AC Voltage
Range
200mV
2V
20V
200V
700V
Input impedance: 10MΩ on all ranges
Frequency range: 40 to 400Hz
Overload protection: 750V rms or 1000V peak continuous an ac ranges, except 200mV AC
range (15 seconds maximum above 300V rms)
DC Current
Range
2mA
20mA
200mA
10A
Overload protection: F 0.2A fuse (20A range not fused)
Maximum input current: 10A, max. 20A during 15 sec
AC Current
Range
20mA
200mA
10A
Overload protection: F 0.2A fuse (20A range not fused)
Frequency range: 40 to 400Hz
Maximum input current: 10A, max. 20A during 15sec
Resistance
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
200MΩ
Capacitance
Range
2000pF
20nF
200nF
2µ F
20µ F
EVM890_v2
Resolution
100µ V
1mV
10mV
100mV
1V
Resolution
1µ A
10µ A
100µ A
10mA
Resolution
10µ A
100µ A
10mA
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
100kΩ
Resolution
1pF
10pF
100pF
1nF
10nF
Accuracy
± 1.2% of rdg ± 3 digits
± 0.8% of rdg ± 3 digits
± 1.2% of rdg ± 3 digits
Accuracy
± 0.8% of rdg ± 1 digits
± 1.2% of rdg ± 1 digits
± 2% of rdg ± 5 digits
Accuracy
± 1.2% of rdg ± 3 digits
± 2.0% of rdg ± 3 digits
± 3% of rdg ± 7 digits
Accuracy
± 0.8% of rdg ± 3 digits
± 0.8% of rdg ± 1 digits
± 1% of rdg ± 2 digits
± 5% of rdg ± 10 digits
Accuracy
± 2.5% of rdg ± 5 digits