Pneumatic Connections; General Precautions - Berner 216069 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9

PNEUMATIC CONNECTIONS

Connect hose coiler to compressed air system at a maximum pressure not exceeding 218 psi. Mount a
quick fi tting or the pneumatic tool on the pipe as it comes out, using the fitting already pressed onto the
pipe. While in use, prevent the pipe from rubbing on sharp edges or on blunt objects. If the pipe is
deteriorated, have a specialist replace it. The coiler is equipped with a spring-loaded coiling system with
automatic blocking device. Always guide the pipe while it is being coiled and take care, while operating, not
to accidentally release the catch. Install the coiler in such a way as to prevent it from causing injury to
personnel or damage to property. If this coiler is destined to be installed on a machine, it is expressly
forbidden to start operating it before the machine where the coiler is installed has been declared to be in
compliance with the directive's norms.

GENERAL PRECAUTIONS

Components have been chosen and used keeping mind the operatingconditions and life span of the
machine. Install the machine so that it presents no danger to exposed personnel, as long as it is used
correctly. No protection or warning will ever be sufficient if the person fails to take certain precautions, if the
machine is not maintained in peak operating condition, and if the following recommendations are not
followed. Learn correct use and adjustment before starting work. Check that personnel using the machine
does so safely and knows its operation. Avoid exposing yourselves and others to unnecessary risks. Insist
that personal protection systems be used, where prescribed. Do not remove, modify, or inhibit SAFETY
DEVICES put in place by the manufacturer, but rather verify that they are not removed or rendered less
effective. Work in an environment that is orderly and free of hazards, with adequate light and room to work
in. Keep the working area free of tools and any other unnecessary object.
In the event of having to do work on the mechanical parts or replace the tube,
contact an after-sales centre. Work done by unauthorised persons is very risky
due mainly to the preloaded spring and will invalidate every type of warranty.
NOT SUITABLE FOR INFLAMMABLE GAS TRANSMISSION.
WARRANTY:
- 12 months from the purchase date.
- The 12-month guarantee is referred to any defect of the new material included in our supply and properly
used; any part subject to wear or damaged by the user (cables, springs, pipes, manifolds, etc.) will
therefore be excluded.
- Any other type of compensation is expressly excluded.
- The warranty consists of free repair or replacement of the parts that, in our final judgment, are materially
or operationally defective.
- Replacement or repair of parts subject to operating wear is excluded.
- Transportation expenses are at buyer's charge.
- The warranty is not applicable when the device is damaged due to misuse.
Malfunction
The hose does not retract completely.
The hose cannot be locked in the
unrolled position.
ANY PROBLEMS
Cause
The hose could be dirty.
The hose is not unlatched.
The hose reel cannot swivel on its
bracket.
The wind-up spring could be broken.
The latching lever could be broken.
Corrective Action
Wipe the hose off with a clean cloth and some
water or other non-solvent liquid.
Pull out the hose and let it retract back to the
hose reel.
Check the wall/ceiling installation and make
sure there is sufficient space for the reel to
move.
Have it checked by a after-sales service agent.
Have it checked by a after-sales service agent.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

216071

Tabla de contenido