Troubleshooting; Maintenance, Repair And Disposal - Reer PI SQ F-NF Manual De Instrucciones

Detector inductivo de seguridad
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Remarks
Remarks
Pack quantity

11 Troubleshooting

LED display → 9.4
Problem
No LED display
Power LED flashes and
sensor does not switch
Sensor does not switch,
not even after undamping
and redamping

12 Maintenance, repair and disposal

If used correctly, no maintenance and repair measures are necessary.
Only the manufacturer is allowed to repair the unit.
After use dispose of the unit in an environmentally friendly way in accordance with
the applicable national regulations.
1: Safety-related logic unit
Unless stated otherwise, all data refer to the 45x45x1 mm reference target plate to IEC
60947-5-2 (FE360 = mild steel) over the whole temperature range.
[piece]
Possible cause
No voltage supply
• Undervoltage
• Overvoltage
Sensor was brought into the
safe state (logic "0"). Cause:
• cross fault between both
outputs A1 and A2
• cross fault between one
output (A1 or A2) and the
supply voltage
• error in the sensor detected
1
Troubleshooting
Apply voltage
Correct the voltage
(→ 10 Technical data)
• Switch the operating volt-
age off and on again
• Check wiring and connec-
tions
• Check external electronics
(e.g. PLC)
• Remove the cross fault
• Replace the unit
UK
Seite 3 von 3
19

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido