WORKING
The PURIQ UV-C BRIGHT ensures crystal-clear water. The sophisticated design and high quality materials
produce high UV-C radiation with a wavelength of precisely 253.7nm. This high level of radiation kills al-
most all bacteria, viruses and even fungi, providing clear and clean water. As a result, the level of added
chemicals (eg chlorine) can be reduced by up to 80%, which ensures more natural, healthier water!
Due to the extra-wide RVS316 housing, the water stays in contact with the UV-C radiation for an
extra-long time. This broad housing also ensures that there is minimal pressure loss during the water
treatment. The housing is polished on the inside to minimize the chance of any dirt sticking to the walls.
Overall, this increases the effectiveness of the UV-C radiation 35%.
The intelligent electronics indicates when the lamp is not producing enough radiation and needs to be
changed. Your device will always be working perfectly!
SAFETY AND INSTALLATION REQUIREMENTS
See the Technical Specifications for the required voltage and current.
The device may only be connected to an electrical installation that meets the legal
requirements. A GFCI (30ma) and earthed sockets are required. If in doubt always use a certified
electrician to install.
The device, the electronics box, the plug and the power cord must be positioned at least 2m
from the tank.
Always keep the plug free from moisture. Ensure that water cannot track down the power cord
to the socket. (See figure 1 for how to loop the power cord).
Never submerge the device in liquid.
The device can withstand a maximum pressure of 3 bar.
The device is only suitable for fresh, not salt, water.
The device is designed to operate with a water temperature between 0 and 40 degrees C.
Outside these temperatures the device must be completely disconnected from the water.
Before use, check the whole device, power cord and plug for damage. In case of any damage,
the device must not be used. Please let your dealer assess any damage.
The device may only be connected if there is a sufficient flow of water.
To avoid possible harm to eyes or skin, the working of the UV-C lamp should only be checked
through the transparent parts of the device. (The system will indicate if the lamp needs to be
changed).
During maintenance, the device and pump must be disconnected from the mains. Be aware
that the device and the lamp can remain hot for up to 10 minutes after being disconnected.
EARTHING THE DEVICE; SEE FIGURE 2
1. Place the strain relief clip (A) about 10-12cm from the eye of the earth cable (B).
2. Slide the eye of the earth cable (B) over the earth pin (C) that is fastened to the housing (D).
3. Slide the first spring washer (E1) over the earth pin (C).
4. Place the hexagonal nut (F) on the earth pin and tighten it.
5. Slide the second spring washer (E2) over the earth pin (C).
6. Slide the strain relief clip (A) over the earth pin (C).
7. Place the last lock nut (G) on the earth pin (C) and tighten it carefully with a spanner #8.
8. Ensure that the sequence follows precisely that shown in figure 2.