INSTALLATION OF THE DEVICE; SEE FIGURE 3
The device must be placed in a dry, well-ventilated area, out of direct sunlight. Never place the device
directly after the pH regulator and/or salt electrolysis. The best position is – if possible – after the filter.
The installation must always be carried out vertically. The electronics box (R) must remain visible so that
the indicator that the UV-C lamp needs changing can be seen. Take into account accessibility for mainte-
nance (see also Maintenance and disassembly).
1.
Undo the lock nut (H) from the housing (D) and keep this for the connecting link (I) under 7.
2.
Carefully unpack the UV-C lamp (J) and slide this into the quartz sleeve (K).
3.
Put the UV-C lamp (J) into the lamp holder (L) and slide this further into the quartz sleeve (K). Make
sure that the O-rings (M1 & M2) sitting properly.
4.
Tighten the nut (N) hand-tight in the housing (D).
5.
Mount the pipe clamps (O) in the required place. The device will hang from these. (Please take into
account the length of the cables, see 6).
6.
Mount the electronics box (R) in the required place. (Please take into account the length of the
cables).
7.
With the lock nut (H), fasten the connecting link (I) to the housing (D), making sure that the O-rings
(P) are seated properly.
8.
Place the device in the pipe clamps (O) and glue the connecting link (I) between the pipes.
9.
Ensure that enough water flows through the device and plug the device into the appropriate
socket. On the electronics box, all the lights will flash and the green one will stay on. You can see
if the UV-C lamp is on by looking through the transparent connecting link (I). Check the whole
assembly for possible leaks.
10.
The device can be turned off by simply pulling the plug out of the socket. The electronics box
records how many hours the lamp has been on.
MAINTENANCE AND DISASSEMBLY
The device needs maintenance at least once per half year. During maintenance, the device must be dis-
connected from the mains. Chalk deposits and possibly algae must be removed from the quartz sleeve
(K) and the housing (D). The UV-C lamp (J) only has to be changed after 12,000 hours of use. The actual
lifetime is dependent on the number of times it is turned on and off. The electronics will indicate when
the lamp has been on for 12,000 hours.
1.
Unplug the device from the mains and close the pipes.
2.
Ensure that the water is drained out of the device.
3.
Loosen the bolt (N) and disconnect the UV-C lamp (J) from the lamp holder (L). If necessary, you
can also replace the lamp (see point 10 to reset).
4.
Carefully raise the quartz sleeve (K).
5.
The quartz sleeve (K) can be cleaned with an appropriate cleaner. After cleaning, rinse the quartz
sleeve (K) thoroughly. Use a soft cloth to avoid scratches!
6.
The housing (D) can now also be cleaned. This can be done with a brush; do not use any chemicals.
7.
After cleaning, place the quartz sleeve (K) back in the housing (D). Ensure that the O-ring (M1 &
M2) is seated properly and that the quartz sleeve (K) slides into the holder.
8.
Put the UV-C lamp (J) into the lamp fitting (L) and slide both into the quartz sleeve (K).
9.
Tighten the nut (N) on the housing (D) hand-tight. (See 9 under Installation of the device).
10.
After changing the UV-C lamp (J), the device needs to be reset. To do this, press and hold button
(S) on the electronics box (R) for 5 seconds. After this the green light will come on.
N.B. To change the housing and/or the electronics box, the earth must be completely disconnected.
The component parts must be saved because they do not come with a new housing or electronics as
standard.
If in any doubt seek the advice of a certified electrician!