Specifications
MODEL
WEIGHT
DXPW4240
140 lbs
(63.5 kg)
* Rated Pressure and Rated Water Flow is within manufacturing tolerance of (+/- 10%)
** HONDA™ is a registered trademarks of the HONDA MOTOR CO., LTD used under license from AMERICAN HONDA MOTOR CO. INC.
Definitions: Safety Guidelines
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to these
symbols.
DANGER: Indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury
which, if not avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS
CONTACT US
AT: www.dewaltpw.com or 1-877-FNA-GAS1
(1-877-362-4271)
HEIGHT
WIDTH
LENGTH
28"
24"
38"
(71.1 cm)
(60.7 cm)
(96.5 cm)
PSI*
GPM*
4200
4.0
(29,958 kPa)
(15.4 L/min)
Important Safety Instructions
DANGER: Carbon Monoxide. Using an engine indoors can kill
you in minutes. Engine exhaust contains high levels of carbon
monoxide (CO), a poisonous gas you cannot see or smell. You
may be breathing CO even if you do not smell engine exhaust.
WARNING: This product and its exhaust contain chemicals
known to the State of California to cause cancer, and birth
defects and other reproductive harm.
• NEVER use an engine inside homes, garages, crawlspaces or
other partly enclosed areas. Deadly levels of carbon monoxide can
build up in these areas. Using a fan or opening windows and doors
does NOT supply enough fresh air.
• ONLY use outdoors and far away from open windows, doors and
vents. These openings can pull in engine exhaust.
• Even when the engine is used correctly, CO may leak into your
home. ALWAYS use a battery-powered or battery backup CO
alarm in your house. Read and follow all directions for CO
alarm before using. If you feel sick, dizzy or weak at anytime,
move to fresh air immediately. See a doctor. You could have carbon
monoxide poisoning.
3
INLET
ENGINE
WATER
cold tap
HONDA GX390**
(100 °F max)
389 cc OHV