S&P RESPIRO 100 Manual De Instrucciones página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
Connection with remoting of wall commands
It is also possible to remote the wall on-off and speed selection controls. Follow the instructions in the "DIRECT CONNEC-
TION" paragraph concerning the modes of connection to the electricity network.
To control the product with wall-mounted switches, during operation the switches on the product must always be positio-
ned on 1 as detailed in the image (Y).
To turn the product on with wall switches, connect a bipolar switch in series to the "L" and "N" supply as detailed in the
picture (a).
Connections are executed as detailed below:
To control the speeds by wall-mounted switch connect the switch's two terminals to the heads "S1" and "S2" as shown.
2b) RESPIRO 100RD / RESPIRO 150 RD
Power supply connection
Before making the connection, the power cables (live and neutral) must be situated in the area of the outlet from the wall.
34
Take the inside wall fi xture (4i) and the tools needed to connect the mains
network to the terminal block.
Properly connect and secure the power cables to the terminal block. "N" and
"L" indication.
It is possible to remote the wall on-off controls. To control the product with in-
tegrated switches, during operation the switches on the product must always
be positioned on 1 as detailed in the image (Y).
To turn the product on with wall switches, connect a bipolar switch in series
to the "L" and "N" supply as detailed in the picture (a).
It is also possible to connect the product to the intelligent home network by
serialising the power to enable programming of the on and off.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Respiro 100 rdRespiro 150Respiro 150 rd

Tabla de contenido