Detecting Failures; Description Of Components On Title Page; Maintenance - Espa TECNOPLUS 15 4M Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 5
Points to take into consideration:
The reference pressure should be 10 meters above
the highest inlet in the system. It is advised to
adjust a reference pressure between 1.5 bars
and 2.5 bars.

4.3. Detecting failures

If the electronic circuit detects a lack of water, it will
stop the pump and the alarm led will flash. The
circuit will run 4 attempts. If it does not manage to
re-establish the pressure due to a lack of water, the
circuit will remain in a failed status until it is
restarted manually.
While the pump is stopped in a failed status and
waiting for a reattempt, the alarm led will flash. After
4 unsuccessful reattempts, the alarm led will remain
on.
The following graph shows the time that passes
between the various reattempts if none of them are
successful.

4.4. Description of components on title page

5. MAINTENANCE

Under normal conditions these pumps require no
special or planned maintenance.
We recommend that in cold weather, when
there‟s risk of freezing, to completely drain
the pipes and pump body by removing the
drain plug.
If the pump is not to be operated for a long
period it is recommended to remove it from
the installation, drain down and store in a dry,
well ventilated place.
ATTENTION: In the event of faults or
damage occurring to the pump, repairs
should only be carried out by an authorised
service agent.
The
Official
Technical
www.espa.com.
When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.
11
EN
Services
list
is
in

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido