Maintenance (To Be Carried Out By Qualified Service Personnel Only) - Bras B-Cube Manual De Instrucciones

Distribuidor de bebidas frias
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

original spare parts from the manufacturer.
ATTENTION
Condenser
fins
are
extreme caution when cleaning.
2
Every month: check that the hexagonal joint
gasket is not worn. If it is, replace the joint itself
with an original spare part from the manufacturer
(see figure 18).
figure 18
3
In the event of strange noises, disconnect
the cooler and call for assistance.
4
In the event of a breakdown, disconnect the
machine as it may start again suddenly.
5
After all repair work, reposition every
component, such as the screws and covers, in
their original position.
6
Once a month: eliminate any dust that has
built up on the condenser filter situated at the
very
sharp.
Use
rear of the machine (see figure 19).
8. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
1
Once a month: eliminate any dust that has
built up on the condenser. Unplug the dispenser
beforehand.
2
Once a year: it is advisable to remove all the
panels and clean inside, including the base and
the internal parts of the panels.
3
Once a year: Check that the bushes on
which the mixers turn are perfectly round and not
worn. Replace them if necessary.
4
Never remove the anti-condensation material
around the outlet pipe of the evaporator (the
copper pipe to the right of the geared motor. If
this material is missing or worn out, replace it
w i t h o r i g i n a l s p a r e m a t e r i a l f r o m t h e
manufacturer.
5
In order to avoid damaging the dispenser,
lubricate the plastic parts only with the grease
provided by the manufacturer or with another
grease compatible with polycarbonate.
23
figure 19