Routine Maintenance - Bras ATLAS L Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN GLIS H
A T L A S L
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM available chlorine concentration or
1 spoon of sodium hypoclorite diluted with 2 liters of water)
according to your local Health Codes and manufacturer's
specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4
Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.

8 ROUTINE MAINTENANCE

1
Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.
2
Monthly: remove the dust from the condenser filter. A
blocked filter will reduce performance and could cause
compressor failure.
Remove the only left panel (from faucet side) unscrewing the
two plastic coated screws (see figure 18).
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3
Replacement of lighted top cover bulbs: remove the fixing
screw located in the upper part of the cover, lift the socket and
replace the bulbs. Reassembly the support and the fixing
figure 18
screw. (see figure 19)
8. 1 MAINTENANCE (TO BE CARRIED OUT
BY QUALIFIED SERVICE PERSONNEL
ONLY)
1
Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
2
Annually: Check if the auger bushings are worn out or
ovalized. If they are, replace them with new ones.
3
When installed, the anti-splash filters inside the slotted
panels must not be removed.
4
Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
5
In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate.
18