The rubber door seals are designed to ensure the closure of the doors to the cold chambers and to
guarantee the sealing of the doors against external elements.
A magnetic strip is housed on the inside of the rubber seal, which adheres it to the frame of the
unit. Over time granular particles can become stuck in the seal due to the effect of the magnet and
these can rust and cause stains.
It is recommended that these door seals are kept free from foreign bodies that can cause rust, as well
as fatty deposits which, over a long period of time, can affect the rubber of the door seal.
Clean them with water, using neutral soap and a damp cloth.
DO NOT USE DETERGENTS OR ABRASIVE PRODUCTS.
9. OPERATIONAL TESTS
• CHECKS IN THE EVENT OPERATIONAL FAILURE
In some situations, operational failure can arise due to simple causes that users themselves can
solve, which is why prior to requesting the intervention of a specialised technician, we recommend
that you carry out the following checks:
The appliance does not work
Check that it is correctly plugged in.
Check that electricity reaches the power outlet.
The internal temperature is too high
Check that there is no heat source nearby.
Check that the grill is not obstructed.
In order to check the cut-off point of the thermostat,
press the "set" button once then release.
Check that the product loaded is perfectly distributed,without blocking the interior air ventilation
exits and that the time elapsed since loading has been sufficient to chill the products.
Check that the doors are properly closed.
In the event of strange or excessive noises
Check the levelling of the unit as this may cause vibrations.
Check that there is no object rubbing against any movable element of the refrigerated unit.
In the event that these checks have not resolved the problem, please contact the customer service
desk in your area providing the following information on the model, serial number and registration
shown on the specification plate.
• NOISE TESTING
• The noise tests were performed in a room without any noise absorption elements and without any
large item placed near to the refrigerated unit.
The noise levels registered in the acoustic tests have been carried out in accordance with the
ISO 230 to 235 standards.
Leq (continuous level) is less than 70 dB. (A)
Lp (acoustic pressure level) is less than 130 dB. (C)
NOTE. (A) (C) Frequency weights.