CANCELLATIONS:
To delete a code, move to the code position and press the C key. The dot indicating a taken
position will disappear. The equipment will emit three short beeps.
To exit the menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a period of 60
seconds and emits two short beeps.
ADVANCED MODE (Mod2):
Allows the complete management of the unit: programming (F.1), cancellations (F.2), time
configuration (F.3) and relay configuration (F.4).
Function is changed using  . To confirm each option, press the C key.
Events monitoring (only visible using the UserPlus).
F.1 PROGRAMMING
Standard programming (Mr_P) (default option, multi-channel mode)
The screen displays the first empty memory position in which we can program a code
(M001). With the   keys we can increase or decrease the memory position. If  
are kept pressed down for more than 3 seconds, the positions increase or decrease
rapidly. If a memory position is taken, this will be indicated by a dot on the screen.
To return to the previous menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a
period of 60 seconds and emits two short beeps.
Special programming (Mr_1 ... Mr34)
Allows selection of the relays that will be activated with the channel programmed from
the transmitter. Example: If you wish to program Channel 1 of the transmitter so that
relays 1 and 3 activate, you need to select option Mr13.
The screen displays the first empty memory position in which we can program a code
(M001).
Using  , we can increase or decrease the memory position. If   are kept
pressed down for more than 3 seconds, the positions increase or decrease rapidly. If a
memory position is taken, this will be indicated by a dot on the screen.
To return to the previous menu, move to the ----- position and press the C key.
If no action is performed, the equipment exits the program automatically after a
period of 60 seconds and emits two short beeps.
F.2 CANCELLATIONS
Individual cancellation
To delete a code, move to the position where the code is located and press the C key.
The dot indicating a taken position will disappear. The equipment will emit three short
beeps.