1. Introduction
23. Polishing mode key
Activates polishing mode. The indicator lights up and the
screen goes out. This mode can also be activated by the
right pedal on the footswitch.
24. Purge key
A short press purges the handpiece powder circuit for a
predetermined length of time of a few seconds.
25. Button to enter or leave standby mode
This button is mainly used for leaving standby mode.
The initialization sequence is started. Only this
button can be used to leave standby mode.
This button can also be used to put the device into
standby mode, but the device goes into standby
automatically after a set time (see § Setting the
standby delay of the device).
Rear panel
26. Team Up connector (optional)
Connection to the electroanalgesia device used during
prophylactic treatment.
27. Compressed air supply filter
Before use the compressed air first passes through a filter
(ref. 2a) with a purge button (ref. 2b). A rapid
disconnection system with an automatic valve enables it to
be connected to the mains.
28. Footswitch connector
Connection for the single or multifunction footswitch pedal.
29. Irrigation kit connector
Refer to kit instructions for details.
30. On/off switch (O/I)
31. Air pressure adjustment
Air pressure is set in the factory. For any adjustment of the
pressure, contact an approved installer of dental
equipment.
32. Drinking water supply connector
Its rapid disconnection system with an automatic valve
enables it to be connected to the supply. A removable filter
is located on the water inlet pipe.
33. Purge of compressed air filter
Press this purge button to eliminate air remaining in the
filter
34. Fan
Do not obstruct the fan at the risk of causing severe
damage to the device.
35. Power socket
Connection to mains electricity is by a standard connector
conforming to IEC 60-320.
36. Fuse housing
Contains the device's fuses.
®
Suprasson
and Suprasson
handpieces
Refer to the relevant instructions.
ProphyPen handpiece
Refer to the relevant instructions.
Multifunction footswitch
37. Left pedal
Activates irrigation without ultrasound. When the irrigation
kit is available, pressing the pedal initiates irrigation
(syringe effect – with a flow rate of about 120 ml/min).
38. Connector
Connection of the device.
39. Range of functions
Each press selects one of the four power modes. The
ultrasound power setting used will be the one memorized,
or by default the factory setting, (the mid position value of
5, except for the top range which is set to 1). Check the
display to view the function selected.
40. Boost
See notes relating to the key 17.
41. Irrigation
See notes relating to the key 21.
42. Right pedal
®
Lux
•
Selected ultrasound function: activates ultrasound
and associated functions that have been previously
selected.
•
Selected polishing function: activates polishing.
3