1. The Triton Powered Respirator DOES NOT provide protection against:
• Poisonous dusts, eg. Garden pesticides.
• Mists, gases or vapour.
• Low oxygen atmospheres (less than normal atmospheric oxygen).
2. The Triton Powered Respirator is not suitable for use in atmospheres containing
flammable gases or explosive dusts (eg spray painting, grain handling facilities,
powder coating etc).
3. The Triton Powered Respirator is not recommended for use outside the temperature
range from -6˚C to 50˚C.
4. The Triton Powered Respirator will give reduced respiratory protection if used:
• with an air flow delivery less than the lower limit, as measured with the supplied
flow meter or without the recommended filters in place (refer "Flow Testing");
• without the air filter unit or with the air filter unit fan "OFF";
• at very high work rates (eg. running) or in high winds.
TECHNICAL SPECIFICATIONS
Respiratory Protection
• The Triton Powered Respirator provides respiratory protection conforming with
AS/NZS 1716 "Respiratory protective devices" to performance Class PAPR P1 or
PAPR P2 when the recommended filters are used (see "Filters").
• Filtered air flow rate approximately 120 litres per minute (5.3 cfm)
• Running time on full charge - minimum 4 hours.
Head Protection
The Triton Powered Respirator incorporates a standard industrial hard hat approved to
AS/NZS 1801. Fits headband size 53 – 60 cm.
Eye Protection
The Triton Powered Respirator incorporates a visor conforming with AS/NZS 1337 "Eye
protectors for industrial applications" to "high impact resistance" performance level.
Hearing Protection
The Triton Powered Respirator incorporates standard earmuffs approved to AS/NZS
1270 "Acoustics - Hearing protectors", 23dB rating.
LIMITATIONS OF USE
- Page 2 -