Important notices
• The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
• The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
• In unfavourable conditions, e.g. with poorly reflecting surfaces,
the maximum deviation may be greater than 3 mm.
• Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
• Measurements made through glass (window panes) can falsify
measurement results.
• An energy-saving function switches the device off automatically.
• Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
Technical Data
Inside measurement range
Precision (typical)*
Laser class
Laser wavelength
Power supply
Dimensions (W x H x D)
Weight (incl. batteries)
Automatic switch-off
Operating conditions
Storage conditions
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
± 0.2 mm/m for greater distances and under unfavourable measuring
conditions such as strong sunlight or weakly reflective target surfaces.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=lrmt7
LaserRange-Master T7
(Subject to technical changes without notice. 17W51)
0,2 m - 70 m
± 0,2 mm / m
2 < 1 mW
635 nm
3 x AAA 1.5 Volt batteries
49 x 115 x 26 mm
145 g
30 sec laser / 3 min device
-10°C...40°C, Max. humidity
20...85% rH, no condensation,
Max. working altitude 2000 m
above sea level
-20°C...70°C,
Max. humidity 80% rH
17
EN