LaserLiner MultiMeter XP Manual De Instrucciones página 24

Ocultar thumbs Ver también para MultiMeter XP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Low Z voltage measurement
12
1.
Low Z voltage measurement
Auto range
13
The „Auto range" function is activated automatically when the meter is switched on. Auto range
searches for the best possible range for each measurement in the corresponding measuring functions.
Activate/deactivate Bluetooth
14
Bluetooth is activated and deactivated by long-pressing button 11.
REL function (comparison measurement)
15
The comparison measurement function takes a measurement relative to a previously saved reference value.
This enables the difference between the current measured value and the saved reference value to be
displayed. Press the „REL" button whilst a reference measurement is being taken in the corresponding
measuring function. The display now shows the difference between the current measurement and
the set reference value. Press the „REL" button again to deactivate the function.
AC+DC function
16
The AC+DC function measures both the AC as well as the DC component to obtain the RMS.
1.
V AC/DC
MAX-/MIN-/AVG function
17
The MAX/MIN/AVG function shows the highest, lowest and average measured values. The measured values
are updated each time a higher or lower measurement is recorded. To activate the function, briefly press
the MAX/MIN/AVG button. „MAX" appears together with the highest value on the LC display. By briefly
pressing the MAX/MIN/AVG button, the device switches from MAX to MIN and from MIN to AVG.
Keep the MAX/MIN/AVG button pressed to exit MAX/MIN/AVG function and return to normal operation.
24
EN
2.
3.
AC/DC
selection
2.
3.
2 sec
Activate
AC+DC
Black
Connect the measuring contacts
to the object to be tested
Black
Connect the measuring contacts
to the object to be tested
Red
Red

Publicidad

Tabla de contenido
loading

Tabla de contenido