CAUTION: Avoid damaging hydraulic hose.
Avoid sharp bends and kinks when routing
hydraulic hoses. Using a bent or kinked hose
will cause severe backpressure. Sharp
bends and kinks will internally damage the
hose leading to premature hose failure.
IMPORTANT: Hydraulic equipment must
only be serviced by a qualified hydraulic
technician. For repair service, contact the
Authorized ENERPAC Service Center in
your area.

IMPORTANT:

equipment by the hoses or swivel couplers.
Use the carrying handle or other means of
safe transport.
CAUTION: Keep hydraulic equipment away
from flames and heat. Excessive heat will
soften packings and seals, resulting in fluid
leaks. Heat also weakens hose materials
and packings. For optimum performance do
not expose equipment to temperatures of
65°C [150°F] or higher. Protect hoses and
cylinders from weld spatter.
DANGER: Do not handle pressurized hoses.
Escaping oil under pressure can penetrate
the skin, causing serious injury. If oil is
injected under the skin, see a doctor
immediately
WARNING: Only use hydraulic cylinders in a
coupled system. Never use a cylinder with
unconnected
becomes extremely overloaded, components
can fail catastrophically causing severe
personal injury.
WARNING: be sure setup is stable before
lifting load. Cylinders should be placed on a
flat surface that can support the load. Where
applicable, use a cylinder base for added
stability. Do not weld or otherwise modify the
cylinder to attach a base or other support.
CAUTION: Avoid situations where loads are
not directly centered on the cylinder plunger.
Off-center loads produce considerable strain
on cylinders and plungers. In addition, the
load may slip or fall, causing potentially
dangerous results.
PUMP MODEL
Electric power:
B = 110/115V-1Ph-50/60Hz
J = 460V-3Ph-60Hz
W = 400V-3Ph-50Hz
Reservoir size (gal) / l.
Nr of Split flow outlets
Oil flow per outlet
3
(in
/min) @ 10,000 psi /
l/min @ 700 bar
Motor size (Hp) / kW
Weight (lbs) / kg
Do
not
lift
couplers.
If
the
B / W
J / W
2,6 / 10
10 / 40
2
2
4
20 / 1,3
94/1,3
33/0,45 33/0,45
1/0,75
7,5 / 5,5
190/86
529 / 240
hydraulic
cylinder

3.0 SPECIFICATIONS

The split flow pump utilizes a single electric motor to
drive a hydraulic pump with multiple outlets. There are
different pump models depending on the number of
outlets
and
specifications for each pump model.
6
2
203/2,8
305/4,2
10/7,5
15/11
1076/488 1160/526 1047/475 1076/488 1160/526 1213/550 1300/590
2
CAUTION: Distribute the load evenly across
the entire saddle surface. Always use a
saddle to protect the plunger.
WARNING: In case of leakage contact
ENERPAC parts. Standard grade parts will
break causing personal injury and property
damage. ENERPAC parts are designed to fit
properly and withstand high loads.
WARNING: Do not use electric pumps in an
explosive atmosphere. Adhere to all local
and national electrical codes. A qualified
electrician
must
do
modification
WARNING: Start the pump with the valve in
the neutral position to prevent accidental
cylinder operation. Keep hands clear of
moving parts and pressurized hoses.
WARNING: These pumps have internal
factory adjusted relief valves, which must not
be repaired or adjusted except by an
Authorized Enerpac Service Center.
WARNING: Enerpac does not recommend
the use of the SFP Series pump with multiple
telescopic cylinders (such as the Enerpac
RT and RLT Series). In a multi-point
application, the plunger stages of each
telescopic cylinder will extend and retract at
slightly different speeds. The cylinders will
never be exactly synchronized and uneven
lifting will result.
CAUTION: To prevent damage to pump
electric motor, check specifications. Use of
incorrect power source will damage the
motor.
CAUTION: Check motor rotation direction to
prevent damage to hydraulic pump (See
paragraph 4.0 installation)
flow.
The
table
J / W
40 / 150
4
65/0,9
101/1,4
153/2,1
7.5/5,5
10/7,5
15/11
installation
and
below
provides
6
8
94/1,30
94/1,30
15/11
20/15