DUOX Amplifier Call:
•
Panels with an address "0" in each block allow for communication with telephones
when picked-up or with the monitors doing an auto-start with it and when the
communication lines are free. If you do not want this feature do not assign this
address to any panels. The monitors also have the option of an auto-start with
panel 1 in your block and panel 0 of the General Entrance.
•
The call is made to the home by pressing the corresponding button.
TECHNICAL FEATURES
Power Supply
Consumption
on standby
active audio
IP43 / IK07
lighting
Audio Power in Residence - Entry Panel Direction
Audio Power in Entry Panel - Residence direction
Operating Temperature
Volume can be Regulated in both directions.
Values:
- Lock-release activation time:
- Exit button activation time:
-
Maximum conversation time: 90 secs
-
Type of panel: sub-block/block/general, (default: block).
-
Block number: 00..99, (by default: 00).
-
Sub-Block number: 00..99, (by default: 00).
-
Panel number: 0..9, (by default: 0).
- Door sensor
time: 000..250, (by default: 000, not active).
- Opening
code: 0000..9999, (by default: not activated).
- Programming
code: 0000..9999, (by default: 4444).
- MÁSTER
panel: not active.
- Monitoring
volume: 0..9, (by default: 5).
-
Buttons' sequential programming time after activity has stopped: 60 secs
-
Buttons' inverse programming time after activity has stopped: 300 secs
Capacities:
•
Calls from the Button Panel: 99.
•
Calls from the Keypad panel:
-
Sub-Block: 99.
- Block:
9999.
- General Entrance: 999999.
•
Number of Panels:
- General entrances: 10.
- Block:
10.
-
Sub-Block: 10.
Page 12
01..99 sec. (Default: 03).
00..99 sec. (Default: 06). Deactivated 00.
18 Vdc
165 mA
275/480 (max) mA
35 mA
1 W
0.15 W
[-25º , +55º C]
[-13º, 131º F]