Problems And Solutions; Technical Specifications - tomado TMA7001W Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
First check the following before submitting the air conditioner for repair.
Problem
The appliance does not switch
on when pressing the on/off key.
The appliance does not cool sufficiently.
The appliance makes a lot of noise.
The appliance does not switch on for a period of 3 minutes
after it has been switched on.
Error code P1
Error code E0 EEPROM
Error code E1
Error code E2
Error code E3
Error code E4
Type number
Voltage
Connected load
Cooling capacity*
EE Class*
EER*
Power consumption kW
Power consumption Standby W
Current consumption nom. A
Air displacement max. m
/h
3
Dehumidification max. ** L/h
Suitable for m
3
Refrigerant / GWP type/gr
Thermostat range °C
Fan speeds
Max. noise level dB(A)
Dimensions (hxwxd)
Nett weight
Protection class
Remote control
Dit symbool betekent dat dit product niet bij het gewone huishoudelijke afval mag worden weggegooid (2012/19/EU). Volg de geldende regels in uw land voor de gescheiden
inzameling van elektrische en elektronische producten.
Als u het product correct afvoert, voorkomt u negatieve gevolgen voor het milieu en de volksgezondheid.
Het verpakkingsmateriaal van dit product is 100% recyclebaar, lever het verpakkingsmateriaal gescheiden in.

PROBLEMS AND SOLUTIONS

Possible cause
The indicator light on the water tank flashes and the water
tank is full.
The room temperature is lower
than the set temperature.
Not all doors and windows are closed.
There are heat sources that are active in the room.
The temperature is set too high.
The air inlet is blocked.
The surface on which the appliance is placed is not level of
flat enough.
The noise is caused by the flowing refrigerant liquid within
the air conditioner.
The internal safety system of the compressor prevents the
appliance from being switched on until 3 minutes have
passed since it was switched off.
The water tank is full.
Technical defect
Sensor for room temperature defective.
Evaporator sensor defective.
Condenser sensor defective.
Operating panel defective.

TECHNICAL SPECIFICATIONS

TMA7001W
220-240Volt ~50Hz
960 Watt
7000Btu/h (2.0kW)
A
2.7
0.8
1
2.0 kW
319
1.79
60
R-290 / 3 /130 g.
17 - 35
2
63 dB(A)
703 x 355 x 345 mm
22.5 kg
IPX0
yes
RECYCLING
EN - 24
Solution
Empty the water tank.
Set the temperature once more.
Make sure that all doors and windows are closed.
Remove the heat sources or switch them off if possible.
Set the temperature once more.
Clean the air inlet grille.
Place the appliance on a flat surface, level if possible.
This is normal.
This delay is normal and the appliance will function normally
after the 3 minutes have passed
Empty the water tank.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.

Publicidad