Descargar Imprimir esta página

mundoclima CL23520 Manual Instalación Y Uso página 40

Publicidad

Idiomas disponibles

Idiomas disponibles

Caution
During heating operation, horizontal airflow will aggravate the
uneven distribution of room temperature.
The louver direction: horizontal airflow is recommended
during cooling operation. Note the downward air flow will
cause condensation on the air outlet and louver surface.
Duct type
Use the following method to regulate the air outlet assembly (sold
separately).
(1) Running in cooling Mode
In order to achieve the cooling effect at all parts of the room, adjust
the fan guide slider to the horizontal air outlet state.
Figure 12.1
(2) Running in heating mode
In order to achieve the heating effect at the ground level of the
room, adjust the fan guide slider to the downwards air outlet state.
Figure 12.2
13. Maintenance
Caution
Before you clean the air conditioner, ensure it is powered off.
Check that the wiring is undamaged and connected.
Use a dry cloth to wipe the indoor unit and remote controller.
A wet cloth may be used to clean the indoor unit if it is very
dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically treated duster on the unit or leave this
type of material on the unit to avoid damaging the finish.
Do not use benzene, thinner, polishing powder, or similar
solvents for cleaning. These may cause the plastic surface to
crack or warp.
Method for cleaning the air filter
a. The air filter can prevent the dust or other particles from
entering the unit. If the filter is blocked, the unit will not work
well. Clean the filter every two weeks when you use it regularly.
b. If the air conditioner is positioned in a dusty place, clean the
filter often.
c. Replace the filter if it is too dusty to clean (the replaceable air
filter is an optional fitting).
1. Open the air return plenum, remove the two screws of the
filter frame, and pull the filter out.
Figure 13.1
2. Dismantle the air filter.
3. Clean the air filter
Dusts will accumulate on the filter along with the unit operation,
and need to be removed from the filter, or the unit would not
function effectively.
Clean the filter every two weeks when you use the unit regularly.
Clean the air filter with a vacuum cleaner or water.
a. The air intake side should face up when using a vacuum
cleaner. (Refer to Figure 13.2)
b. The air intake side should face down when using clean water.
(Refer to Figure 13.3)
For excessive dusts, use a soft brush and natural detergent to
clean it and dry in a cool place.
38
Figure 13.2
Figure 13.3

Publicidad

loading

Este manual también es adecuado para:

Cl23529