THIS DOCUMENT MUST BE FRAMED AND MOUNTED IN VIEW AND ADJACENT TO THE FIRE CONTROL PANEL.
DX Connexion
User Guide for the DX Connexion Series
GB
Fire Alarm Control Panels
User Levels
• The DX Connexion Series Fire Alarm Control Panels
have three available user levels for panel operation
and control. At all three levels, the LCD is the primary
status indicator of the panel; detailed information
on alarms and faults is presented together with
appropriate panel status LED indications.
C
• User Level 1: the user control keys are inhibited restricting
the front panel function to indication only. The Mute Buzzer
and Show Alarm Zones user function keys may be operable.
• User Level 2: the user control keys are active allowing
1
control for Mute Buzzer, Silence/Resound, System
4
OK
GHI
7
PQRS
Reset, Extend Delay, Show Alarm Zones and Evacuate.
FIRE
FAULT
DISABLEMENT
TEST
EN54-2
User Level 2 also allows test and disable/enable
EN54-4
BUZZER MUTED
SYSTEM FAULT
DELAYED MODE
SOUNDER FAULT
SOUNDERS DISABLED
SOUNDERS SILENCED
POWER
SUPPLY FAULT
functions to be performed. User Level 2 is reached by
entering a passcode from User Level 1 or turning the
keyswitch, if fitted and configured for this function.
• User Level 3: allows full system configuration
and programming. This level is for use by the
installer/maintenance provider only.
• Consult the DX Connexion Series User Manual for detailed
information on user levels and operation. To access
key and, using the numeric keypad,
Level 2, press the
OK
press '5' and enter the passcode at the screen prompt.
Periodic Testing
Daily: Check that the panel indicates normal operation.
If not, record the fault in the log book and report to the
maintenance provider. Check any previously-reported faults
have received attention.
Monthly: At least one call point or detector (from different
zones each month) should be operated to test the fire
panel and any connected alarm/warning devices. Where
permissable, any link to the fire brigade or remote centre
should be operated. If any faults exist, record these in the log
book and report to the maintenance provider.
Para más información:
www.morley-ias.es
Honeywell Life Safety Iberia
C/Pau Vila 15 19
08911 Badalona (Barcelona)
España
T: 902 03 05 45
E: infohlsiberia@honeywell.com
996 214 002 1 | Rev 02 | 08/16
© 2016 Honeywell International Inc.
Fire Safety
DX Connexion Series Controls and Displays
NUMERIC KEYPAD
(MENU OPTION SELECTION KEYS)
0 9 Keys
For number entry. Also used for alphabet
entry during programming and configuration.
FIRE
FAULT
BUZZER MUTED
SYSTEM FAULT
SOUNDERS SILENCED
SOUNDER FAULT
POWER
SUPPLY FAULT
Press to cancel a change or return to a
previous menu.
C
C
MUTE BUZZER
Press to back-space when correcting entries
2
3
ABC
DEF
SILENCE/ RESOUND
5
6
JKL
MNO
SYSTEM RESET
such as passcodes.
8
9
TUV
WXYZ
EXTEND DELAY
0
C
SHOW ALARM ZONES
EVACUATE
F1
F2
MENU NAVIGATION KEYS
Press
a menu option. Press , , and
keys to select and scroll through
Level 1 display functions for fire, fault,
disablement and test conditions.
SYSTEM
STATUS
LEDS
C
Normal Condition
Green AC Power LED only is on.
Mains Power Failure
Supply Fault LED lights and internal buzzer sounds intermittently.
Fire Alarm Condition
FIRE LED is on. Zone Fire LEDs (if fitted) indicate the location of the alarm.
The internal buzzer sounds continuously.
Fault Condition
The LCD displays fault information. General Fault LED and system LEDs
indicate the type of fault. The internal buzzer sounds intermittently.
MUTE BUZZER
1
2
3
ABC
DEF
SILENCE/ RESOUND
4
5
6
GHI
JKL
MNO
OK
SYSTEM RESET
7
8
9
PQRS
TUV
WXYZ
EXTEND DELAY
0
C
SHOW ALARM ZONES
DISABLEMENT
TEST
EVACUATE
EN54-2
EN54-4
DELAYED MODE
F1
SOUNDERS DISABLED
F2
Key
FIRE
BUZZER MUTED
FIRE
Key
SOUNDERS SILENCED
BUZZER MUTED
POWER
SOUNDERS SILENCED
POWER
to confirm changes or select
OK
LCD
FIRE
FAULT
DISABLEMENT
SYSTEM FAULT
DELAYED MODE
BUZZER MUTED
SOUNDER FAULT
SOUNDERS SILENCED
SOUNDERS DISABLED
POWER
SUPPLY FAULT
OK
USER CONTROL KEYS
Mute Buzzer
Press to silence the internal buzzer.
Silence/Resound
Press to silence the sounders. Press
again to re-activate.
MUTE BUZZER
1
2
3
ABC
DEF
MUTE BUZZER
SILENCE/ RESOUND
4
1
5
2
6
3
OK
GHI
ABC
JKL
DEF
MNO
System Reset
SILENCE/ RESOUND
SYSTEM RESET
7
4
5
8
6
9
PQRS
TUV
WXYZ
OK
GHI
JKL
MNO
EXTEND DELAY
SYSTEM RESET
7
8
0
C
9
PQRS
TUV
WXYZ
Press to cancel all alarm conditions
EXTEND DELAY
SHOW ALARM ZONES
0
C
FAULT
DISABLEMENT
TEST
EN54-2
EVACUATE
SHOW ALARM ZONES
EN54-4
SYSTEM FAULT
DELAYED MODE
and reset the panel after cause of
FAULT
DISABLEMENT
TEST
EN54-2
F1
EVACUATE
EN54-4
SOUNDER FAULT
SOUNDERS DISABLED
SYSTEM FAULT
DELAYED MODE
F2
F1
SUPPLY FAULT
SOUNDER FAULT
SOUNDERS DISABLED
alarm has been corrected.
F2
SUPPLY FAULT
Extend Delay
Press to acknowledge Stage 1
Delayed Alarm. Stage 2 delay period
starts.
Show Alarm Zones
Displays fire alarm information. If
there is more than one zone in alarm,
scrolls through these zones.
Evacuate
OK
Press to turn on ALL Sounder
OK
Outputs, i.e. evacuate building
manually.
MUTE BUZZER
1
2
3
ABC
DEF
SILENCE/ RESOUND
4
5
6
GHI
JKL
MNO
OK
SYSTEM RESET
7
8
9
PQRS
TUV
WXYZ
EXTEND DELAY
0
C
SHOW ALARM ZONES
TEST
EVACUATE
EN54-2
EN54-4
F1
F2
KEY SWITCH
(OPTIONAL)