LOCK-RELEASE TIMMING
There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the 'BS' and '-' terminals).
BUTTON Panel Programming
Carry out the following steps:
1.
With the power supply disconnected, short circuit the «Bs» and «-» (negative) amplifi er terminals.
2.
Maintaining the aforementioned short-circuit connects the power system. The amplifi er will
generate as many ''beeps'' as seconds programmed for the opening time from the residence.
2.1.If you want to change this value, you must press any call button as often as the seconds
you wish to program.
2.2.If you do not want to change, just wait 10 seconds without pressing any call button.
3.
Then
the amplifi er will ''beep'' for every second the opening time has been programmed from
the exit button.
3.1.If you want to change this value, you must press any call button as often as the seconds
you wish to program.
3.2.If you do not want to change, just wait 10 seconds without pressing any call button.
4. Exit Programming:
To exit programming mode, wait 10 seconds without pressing any key. A «beep beep» tone will
sound to indicate that you have exited time programming mode.
5. From that moment you can remove the short-circuit between the terminals «Bs» and «-»
(negative) from the amplifi er and you can use the amplifi er as normal.
Notes:
• Values:
- Lock-release time: 01..99 sec. (Default: 03).
- Exit button time: 00..99 sec. (Default: 06).
• On mixed panels with buttons and keypads this method is not permitted and changes must be made via the keypad..
VOICE ASSISTED Programming
You can also program the opening times via the amplifi er´s voice assisted confi guration.
For more information see ANNEX: Voice assisted confi guration in button panels. Instructions
included with this equipment.