Replacing Existing Prox Tags
To keep the same user code and number, but enroll a new tag due to loss of the old one
1.
Press Prox Tag Programming.
2.
Confirm that you want to overwrite the existing tag by pressing Yes.
3.
Place the prox tag near the tag reader
will be displayed and the keypad will beep.
User Options
Keypad Configuration
Home > More > User Options > Keypad Config
From this screen you can access the following options:
• Brightness
• Nightlight
• Screen off after X:XX:XX
• Verbal Options
• Tone Control
• Volume
• Voice Volume
• Languages
Event Buffer
Home > More > User Options > Event Buffer [Master Code]
Your panel keeps a record of events that have occurred on the system, such as when a zone is bypassed, an alarm
occurs or a zone is violated. The event buffer (log) displays the date, time and the full description of the event(s),
including zone/user label. The log is organized from the most recent event (top) to past events (down). The left arrow
scrolls forward in time. The right arrow scrolls back in time. The Back returns you to the Home screen. This screen
will time out to the Home screen after 30 seconds of inactivity.
User Functions
Home > More > User Options > User Functions [Master Code]
The user functions menu can only be accessed when the system is disarmed. Only the master code or a user code with
the supervisor attribute enabled may be used to access this mode. From this screen you can access the following
options:
• Time and Date
• System Test
• Late to Open Programming
• Late to Open - On/Off
• Auto-Arm Programming
• Auto-Arm On/Off
• Enable DLS
• User Call-Up
• User Walk Test
Troubles
When a trouble condition is detected, the Trouble (
every 10 seconds. Press anywhere on the keypad to silence the beeps. Press (
press the specific option for further information.
Troubles
Service Required
(Press for more
details)
AC Trouble
Phone Trouble
Communication
Failure
Device Fault
Device Tamper
Device Low Battery
at the top of the keypad. The message "Tag Enrolled Successfully"
Comments/Further Options
• Panel low battery
• Bell circuit trouble
• General system trouble
• General system tamper
If the building and/or neighborhood has lost electrical power, the system
will continue to operate on battery for several hours.
The system has detected that the telephone line is disconnected.
The system attempted to communicate with the monitoring station, but
failed. This may be due to Telephone Line Fault.
• Keypads
• Repeaters (Impassa SCW9055/57)
• Zones
• Sirens
• Keypads
• Repeaters (Impassa SCW9055/57)
• Zones
• Sirens
• Repeaters (Impassa SCW9055/57)
) indicator will turn on, and the keypad will sound double beeps
• Module supervision
• Rf Jam condition detected
• PC5204 low battery
• PC5204 AC failure
• Zones
• Sirens
• Keypads
• Prox tags
) to view the trouble condition, and
Action
Call for service
Call for service
Call for service
Call for service
Call for service
Call for service
Call for service
6