1. GENERAL WARNINGS

The installation of a stove must be done according to the local, national or European regulations.
Our liability is limited to the supply of the equipment. The installation must be done according to the procedures expected for this kind of equipments,
according to the indications included in this manual and the rules of the profession. The fitters must be qualified, with official license and they will work
for enterprises that accept responsibility of the installation.
The manufacturer will not be responsible for the modifications made to the original product without the prior written permission as well as for the use of
non-genuine spare parts or pieces.

2. GENERAL DESCRIPTION

The equipment that you have purchased contains the following pieces:
-
Stove body placed on the pallet.
-
Inside the combustion chamber you can find: a box/bag with a thermal glove that allows us to handle the air controls, door, etc, in order to
avoid burns. The smoke baffle-plate.
The equipment is made of several elements of steel sheets welded, with different thickness, and, depending on the model, pieces of cast iron or
vermiculite (orange-coloured refractory material that covers the walls). It also has a panoramic door with vitro ceramic glass (resistant up to 750ºC) and
ceramic cord for the air tightness of the combustion chamber.
Heating is produced by:
a.
Convection: because the air passes through the body, the stove gives off heat.
b.
Radiation: through the vitro ceramic glass and the body the heat is irradiated towards the environment.
The models have some settings for a perfect combustion control:
The primary air intake
Controls the air that passes through the ash pan and the grate towards the fuel. The primary air is necessary for the combustion process.
The ash pan should be emptied frequently so that the ash does not block the primary air intake for the combustion. Also, the primary air rekindles the fire.
The regulation is located under the door and you have to make a left-right moving: the movement to the right means more flow entrance.
The secondary air intake
Favors the carbon that was not burnt during the first combustion can suffer
a post-combustion. This increases the efficiency and assures that the glass keeps clean. The entrance is located at the top between the door and the
glass. Is not adjustable
Baffle plate
The baffle plate is a fundamental part for the proper operation of the stove. It must be placed in the right position and the stove must not be used without
the baffle plate. This would invalidate the warranty.
WARNING!
The lack of the baffle plate causes an excessive draw. This causes a fast combustion, excessive wood consumption and the overheating of the
equipment.
Due to safety reasons during the transport, the baffle plate is not assembled. You will find it inside the combustion chamber. To place it properly, follow
the next steps:
The baffle plate must be rested on the side supports of the combustion chamber.
Primary air regulation
Secondary air intake