Descargar Imprimir esta página

Model Specifications; Installation Overview - ClassicFlame BUILDERS BOX Serie Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH
CSA AND UL STANDARDS FOR FIXED AND LOCATION DEDICATED ELECTRIC ROOM HEATERS.
MODEL NUMBER
36EB110-GRT
36EB220-GRT
36EB111-GRC
36EB221-GRC
THE INSTALLATION OF THE BUILDER BOX MUST COMPLY WITH THE APPLICABLE
LOCAL AND / OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.
THIS INSTALLATION SHOULD BE ENTRUSTED TO ONLY QUALIFIED
(Please read all instructions and user manual before installation)
Section 1.) Prepare product for installation.
Section 2.) Rough in framing following the recommended dimensions.
Section 3.) Recommended power supply wire specifications.
Section 4.) Mount the unit.
Section 5.) 120V wiring instructions.
Section 6.) 208/240V wiring instructions.
Section 7.) Install control box.
Section 8.) Check & test.
Section 9.) Electrical wiring diagram.
LISTINGS AND CODE APPROVALS

MODEL SPECIFICATIONS

DESCRIPTION
36" TRADITIONAL
36" TRADITIONAL
36" CONTEMPORARY
36" CONTEMPORARY
PERSONNNEL WHERE REQUIRED BY LAW.

INSTALLATION OVERVIEW

VOLTAGE
120
208/240
120
208/240
WARNING
E-2
RATED POWER
BTU
WATTS
1440
4400
2100/2800
6700/8900
1440
4400
2100/2800
6700/8900
AMPS
12
10.1/11.7
12
10.1/11.7

Publicidad

loading