Commissioning; Supply Pressure; Technical Data - BRÖTJE VR 415 VA 1001-1000 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18

4. Commissioning

4.1 Supply pressure

4.2 Technical Data

Model
Gas valve
Nominalheat load
Heating
Nominalheat output 80/60°C Natural gas
50/30°C Natural gas
Nominalheat load
Heating Propane
Nominal heat output 80/60°C Propane
50/30°C Propane
CO
-Content
2
Model
Gas valve
Nominalheat load
Heating
Nominalheat output 80/60 °C Natural gas
50/30 °C Natural gas
CO
-Content
Part load Natural gas
2
Full load Natural gas
7312109 - 03 - 28082019
Supply Pressure
The supply pressure must lie between the following values:
for natural gas:
- min. 18,0 mbar
- max. 25.0 mbar
For LPG:
- min. 42,5 mbar
- max. 57,5 mbar
The supply pressure is measured as pressure in the gas flow at the measuring nozzle
of the gas valve.
The boiler must not be started up when the supply pressures are outside the said
range. The gas supply company should be informed.
SGB 125
VR415VA
10011000
Natural gas
kW 20,0 - 125,0 28,0 - 170,0 35,0 - 215,0 42,0 - 260,0 48,0 - 300,0
E, LL
kW 19,2 - 121,6 26,8 - 165,8 33,5 - 210,1 40,2 - 254,5 45,9 - 294,0
E, LL
kW 21,3 - 133,1 29,8 - 181,3 37,4 - 229,6 44,9 - 278,1 51,4 - 321,3
E, LL
kW 35,0 - 125,0 35,0 - 170,0 48,0 - 215,0 58,0 - 260,0 58,0 - 300,0
kW 33,5 - 121,6 33,5 - 165,8 46,0 - 210,1 55,5 - 254,5 55,5 - 294,0
kW 37,2 - 133,1 37,3 - 181,3 51,2 - 229,6 62,0 - 278,1 62,1 - 321,3
Natural gas
%
9,1 - 9,5
E, LL
Propane
%
10,8 - 11,2
SGB 400
Natural gas
kW
82,0 - 402,0
E, LL
kW
80,4 - 393,8
E, LL
kW
88,9 - 426,0
E, LL
%
E, LL
%
E, LL
Gas valve VR415, 420, 425, 434
Commissioning
SGB 170
SGB 215
VR415VA
VR420VA
10011000
10041000
9,1 - 9,5
9,1 - 9,5
10,8 - 11,2
10,8 - 11,2
SGB 470
VR434VE 5021-0000
95,0 - 469,0
93,0 - 459,0
102,8 - 496,6
8,7 - 9,0
9,0 - 9,3
SGB 260
SGB 300
VR425VA
VR425VA
10091000
10091000
9,1 - 9,5
9,1 - 9,5
10,8 - 11,2
10,8 - 11,2
SGB 540
109,0 - 539,0
106,6 - 526,9
117,7 - 570,3
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vr 420 va 1004-1000Vr 425 va 1009-1000Vr 434 ve 5021-0000