INSTRUCTIONS MANUAL
Digital clamp meter
C-LOGIC 8900
Code: 301000060
ENGLISH
GENERAL DESCRIPTION
The 3-phase clamp-type digital power meter is a handheld intelligent harmonic power tester,
with both functions of digital current testing and power testing. The tester is comprised
of three channels including voltage, current, and power as well as a micro single chip
system, and it is equipped with a powerful software for measurement and data processing
functions; it can measure, calculate, and display voltage, current, active power, power factor,
apparent power, passive power, frequency, harmonic parameters, with stable performance
and operation convenience. The meter is especially suitable for the measurement and
examination of on-site power equipment and power-supplying circuits; with hand-held clamp
structure, small volume, and lightweight, it can be easily carried by the user, which makes
it easy and fast for doing measurement. The meter is your ideal choice for measurement of
single-phase/ three-phase power.
SAFETY INSTRUCTIONS
The three-phase clamp-type digital power meter is designed and manufactured in
accordance with international standard, IEC61010-1, and international safety specification,
IEC1010-2-032, and the meter strictly follows the safety standard of double-insulation AC
600 V CAT III.
SAFETY REQUIREMENTS
Please carefully read the instruction manual before using the tester, and pay special
attention to "Warning" content. Please follow instructions under "Warning".
• Please be very careful when test voltage is higher than AC 30 V, and do keep in mind that
your finger shall not exceed the hand-shielding part of the test probe.
• Do not measure voltage which is higher than the allowed input limit.
• Before use, please check the meter and test probe; do not carry out testing in case the test
probe is naked, tester housing is damaged, or there is no LCD display, etc..
• It meets requirements of safety standards only when the meter is used together with the
supplied test probes. In case the test probe is damaged and needs replacement, it is required
to replace it with a test probe of the same model and identical electrical specifications.
• Please never carry out any voltage measurement whenever the test probe is inserted in
any current outlet.
• Please do not expose the meter to strong light, high temperature, or dampness.
Warning
Before use, please carefully read this instruction manual. Especially safety contents!
REPLACING TEST LEADS
Replace test leads if leads become damaged or worn.
Warning
Use meet EN 61010-031 standard, rated CAT III 600V, or better test leads.
REPLACING THE BATTERIES
Warning
To avoid electric shock, make sure that the test leads have been clearly move away from
the circuit under measurement before opening the battery cover of the meter.
Warning
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or
rechargeable (ni-cad, ni-mh, etc) batteries.
• If the sign "
" appears, it means that the batteries should be replaced.
• Loosen the fixing screw of the battery cover and remove it.
• Replace the exhausted batteries with new ones.
• Put the battery cover back and fix it again to its origin form.
EN
Note:
Do not reverse the polarity of the batteries.
ACCESSORIES
• Short Instruction manual
• 1.5V AA Baterry
• Test probe
• Test clip
• Interface cable
• PC Software CD
• Package box
FULL MANUAL DOWNLOAD
1
4
1
3
1
1
1
You can download the complete
manual at the URL
http://www.c-logic.es/manuales
MANUFACTURER:
MGL EUMAN S.L.
Parque Empresarial de Argame,
C/ Picu Castiellu, Parcelas i-1 a i-4
E-33163 Argame, Morcin
Asturias, España (Spain)