Real Time Analyzer (Rta) - Phonic PAA6 Manual Del Usuario

Ocultar thumbs Ver también para PAA6:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Real Time Analyzer (RTA)

This function analyzes the audio received through either the built-in microphones or line in connec-
tors, divided into a number of separate bands in 1, 2/3rd, 1/3rd or 1/6th octave resolution (see figure
15). Each frequency band is graphed as a vertical bar on the RTA, the height of which represents the
level – whether in dB SPL, dBu, etc – of the individual octave or sub-octave bands. A 60 dB range is
displayed at any one time, and users can scroll up the page slightly if clipping occurs, or scroll down
if the results aren't visible.
Frequencies from 20 Hz to 20 kHz can be monitored individually by selecting the frequency band on
screen. The level and frequency will appear to the left of the screen. Measurements can be taken
at four different response times (35 ms, 125 ms, 250 ms, and 1 sec, shown in figure 16) and in four
weighting types (A weighting, B weighting, C weighting and Flat, as shown in figure 17). For more info
on response times and weighting, please consult the appropriate sections.
PAA6
figure 15
figure 16
17

Publicidad

Tabla de contenido
loading

Tabla de contenido