Obstacle Detection Functioning - Erreka IZAR O MAXI VIVO-D102 Manual Del Instalador

Ocultar thumbs Ver también para IZAR O MAXI VIVO-D102:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DESCRIPTION OF THE PRODUCT
4

OBSTACLE DETECTION FUNCTIONING

The door can detect an obstacle in three ways:
A- Detection by opening safety device (SG.A)
Before opening
If the opening safety device (SG.A) is activated during
opening, the door does not start opening and shows
CLC4.
During opening
If the opening safety device (SG.A) is activated during
opening, the door continues to open.
B- Detection by photocell or safety strip in closing (SG.C)
During opening
If, during opening, the closing safety device (SG.C) is
activated, the door continues to open.
C- Direct detection (built-in safety)
During opening
If, during opening, the door collides with an obstacle, it
inverts direction and slightly closes. The door remains
on standby until a key command is received. When the
key command is received, it closes completely.
38
Installation Manual
During closing
If the opening safety device (SG.A) is activated during
closing, the door continues to close.
During closing
If the closing safety device (SG.C) is activated during
closing, the door inverts operation direction and opens
completely.
During closing
If, during closing, the door collides with an obstacle, it
inverts operation direction and opens completely.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Izar o maxi vivo-d102m

Tabla de contenido