INSTALLATION
Power supply and operator connections
This control board has been designed and
constructed for connection to IZAR or MAXI
operators with encoder. The connection of
other operators may
operation, and may produce accidents and
failures. If in doubt, check with an ERREKA
agent.
O
These operators do not require capacitors for
operation.
MGN
VIVO-D102:
230V, 50-60Hz
VIVO-D102M:
125V, 50-60Hz
IZAR Operator with encoder
F1
Main fuse (D102: 2.5A; D102M: 4A)
TRAFO
Transformer
(supplied installed and connected)
STOP
Release switch cable connectors (normally
closed), only in IZAR operators with encoder
and release
42
Installation Manual
result in incorrect
Current
regulations
magnetothermic switch to feed the control
board must be fitted. The contact separation at
all poles must provide a total disconnection
under category III overvoltage, in accordance
with
installation
regulations.
characteristics (rated current, voltage, etc.)
must be suitable for the facility and the
elements used.
Connect the MGN magnetothermic switch to feed
the control board as shown in the attached diagram.
G1
Blue (motor)
G2
Red (motor)
P14 (GND) Mesh (encoder mesh) (–)
P15 (SNG1) Green (encoder signal) (S)
P13 (V+)
Brown (encoder power supply) (+)