Note: If the security devices (TB, FTCI, FTCS) are not at rest or DIP 2 is in the "ON" position,
time programming will not be enabled.
2. Press the "P1" button (or activate either "TD" or the radio control) to start the opening cycle.
Note: During time programming the activation of TB, FTCI or FTCS will force the gate and the
time count to stop; as soon as the security devices are reset the time count and gate move-
ment will continue.
3. When the opening travel limit is activated the motor will block but the work time count will
carry on in order to give a slightly higher time margin with respect to the exact manoeuvring
time.
4. Press the "P1" button (or activate either "TD" or the radio control): the work time count will
end. The "POS. FCC" output is now flashing at slower intervals: the pause time count has
now started.
5. When the pause time is sufficient, press the "P1" button again (or activate either "TD" or the
radio control) the closing cycle will start and you will exit the programming procedure.
***** READ THE FOLLOWING NOTES CAREFULLY *****
• When the unit is powered up; if the opening travel limit is active and automatic re-closing
has been selected the boom/shutter will close after the pause period has expired.
• When the unit is powered up with the boom/shutter not completely closed the logic will
only allow the opening command and not the closing command. The only exception
occurs when the opening travel limit is active or if the "closing memory" function has
been selected. Therefore the programmer cannot detect an active "FCC" and will be set
to the completely open status
• With the barrier fully open, activating "FTCI" or "TA" will force a pause time reset.
Alarm indications
1) Wrong parameters in EEPROM memory
If there is a data read error from EEPROM the "POS. FCC" output will indicate the error
by activating intermittently: the system will be blocked. You will have to enter work time
programming to correct the error. Pressing the "P1" button will force the LED "L2" to flash
straight away: wait until it flashes rapidly indicating that you have entered the programming
mode.
2) Simultaneous travel limit activation
Simultaneous travel limit activation will cause the programmer to block as long as the prob-
lem exists. The warning light will stay on for 3 seconds and off for 3 seconds.
When the travel limits have been freed an automatic reset will occur and normal operation
will return.

REMOTE CONTROL

The dynamic command can be also be controlled via radio by inserting a Cardin standard
radio receiver card into the "R1" (fig.1) interface slot. It is possible to manage the dynamic
function "TD" open-close. (or open-block-close-block), see "DIP 3" under the heading "dip-
switch settings" and the blocking command (only with a two channel receiver card). If you
use a single channel receiver card remember to close the jumper "J3". For ulterior information
consult the instruction manual supplied with the receiver card.

FUNCTION MODE

DIP-SWITCH SETTINGS (D1)
DIP 1:
On =>
automatic re-closing enabled.
Off =>
automatic re-closing disabled.
DIP 2:
On =>
"manual mode" activated.
Off =>
"manual mode" disactivated.
DIP 3:
On =>
"TD" mode: "open-close" with inversion only during the opening stage.
Off =>
"TD" mode: "open-block-close-block".