6
FOTOTEST
MASTER/
7
SLAVE
BACK
8
JUMP
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10 and
11 will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see page 25) of the controller.
SENSITIVE
12
EDGE
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in clos-
ing [see motor instructions].
When you have completed the installation procedures:
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according to
the automation model (see table of dip-switches 9-10-11, "Logic adjustments" section).
It is recommended to start the learning process with the gate at 0,5 m from closing mechanical stop.
Press without releasing the PROG button till the DL8 LED starts flashing (yellow):
-
the automation starts to open slowly looking for the opening limit stop;
If the automation closes instead of opening, stop the run of the gate (by cutting the pho-
tocells or closing the STOP contact), invert the polarity of the motor, take the gate in the
closed position (on the mechanical stop) and restart the procedure from the beginning.
Note: if the automation does not work, check the input connections. The DL6, DL5, DL4
and DL3 green LEDS must be on.
-
once the limit stop is reached, the automation starts closing looking for the closing limit stop (in
this phase the control unit gathers all the parameters regarding the run);
-
the automation carries out one complete opening to optimize the opening power;
-
after a short pause, the automation carries out one complete closure to optimize the closing power.
WARNING:
-
The procedure can be stopped by pressing the STOP button.
20
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-
On
COMM instructions).
enables the SLAVE mode in the master/slave configuration (see T-
Off
COMM instructions), or standard operation (single motor).
once reached the mechanical stop (either while opening or closing) the
On
operator will reverse slightly to avoid jamming between pinion and rack.
Off
function not activated.
Dip 11 Automation
Off
T-ONE5BE up to 400 Kg
Off
T-ONE5BE more than 400 Kg
Off
not used
Off
not used
On
not used
On
not used
On
not used
On
not used
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
Off
FIXED EDGE (NC contact – terminal No. 10).
K127MA