SÉCURITÉ
General: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
IEC 61326-1: Portable Electromagnetic Environment;
IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or
use conductively coupled radio-frequency energy which is
necessary for the internal functioning of the equipment itself.
Class A: Equipment is suitable for use in all establishments
other than domestic and those directly connected to
a low voltage power supply network which supplies
buildings used for domestic purposes. There may be
potential difficulties in ensuring electromagnetic
compatibility in other environments, due to conducted
and radiated disturbances.
Caution: This equipment is not intended for use in
residential environments and may not provide adequate
protection to radio reception in such environments.
CARACTÉRISTIQUES ÉLECTRIQUES VOLTS C.C.
(Précision à 23 °C ±5 °C, <75 % d'humidité relative)
DC VOLTS
Gammes
Résolution
Précision
Impédance d'entrée
Protection contre les
surcharges
1000 mV, 10 V, 100 V, 1000 V
(mode de gamme automatique/
manuel)
100 μV
±(0.25 % de lecture + 5 chiffres)
10 MΩ
1000 V c.c. ou 750 V c.a. eff.
60