2=1. CONNECTING
WIRES FOR OUTDOOR UNIT
• Be sure to use special circuits for room air conditioner.
• Wiring work should be based on applicable
technical standards.
• Wiring connections
should be made following
the diagram.
• Screws should be tightened
so they won't loosen.
ELECTRICAL
SPECIFICATIONS
OUTDOOR
UNIT
Power supply (V, PHASE, Hz)
Max. Fuse size (time delay) (A)
Min. Circuit Ampacity
(A)
Fan motor (F.LA)
(R.LA)
Compressor
(LR.A)
Control voltage
MXZ-2B20NA
208/230,1,60
2O
15
0.96
10.1
15
lndoorunit-Remote
controtter:(Wireless)
lndoorunibOutdoorunit:
DC12-24V
1) Remove the service panel.
2) Fix the conduit
connector
to conduit
cover with lock nut then secure
it
against unit with screws.
3) Fix the conduit cover to the outdoor unit then secure it with screws.
4) Connect
power supply cord and indoor/outdoor
connecting
wire to the ter-
minal block.
(Leave some slack in wires to allow easier servicing.)
5) Close the service panel securely. Make sure that 3-2. PIPE CONNECTION
is completed.
Grounding
terminal
/
cCoOndr u,t
Lock nut
Connector
Remark:
*
A disconnect
switch should be required.
Check the local code.
** Use a ring tongue terminal
in order to connect
a ground wire to terminal
CONNECTING
WIRES AND CONNECTING
GROUND
WIRE
• Use solid conductor AWG14 or stranded conductor
AWG14.
• Use double insulated copper wire with 600 V insulation.
• Use copper conductors
only.
Follow
local electrical
code.
r INDOOR UNIT[A] "
[ INDOOR UNIT[B']"
,
Terminal
block
,
Terminal
block
I
I
-_---_---_--,, i Grounding
[._ ._o_._o_.i
_rn
ina i **
[-?_-°_-°_i_
rninai**
-_----_---_--: i G.... ding
208/230VAC
i
i
i
iDi .......
t 208/230 VAC i
iDi
t
.......
1phase 60 Hz
::
switch *
1phase 60 Hz _
switch *
Terminal
block 1
Power supply 208/230 V AC
1phase 2wires 60 Hz
OUTDOORUN,T
Ground
,
Connect
wires to the matching
numbers
of terminals.
,
Be sure to attach
each screw
to its correspondent
terminal
when securing
the cord and/or the wire to the
terminal
block.
POWER SUPPLY CABLE AND GROUND
WIRE
• Use solid or stranded conductor AWG14.
• Use copper conductors
only.
Follow
local electrical
code.
WARNING:
Use the indoor/outdoor
unit connecting
wire that meets the Standards
to connect
the indoor and outdoor
units and fix the wire to the terminal
block securely
so that no external
force is conveyed
to the connecting
section
of the terminal
block.
An incomplete
connection
or fixing
of the
wire could
result
in a fire.
I For future servicing,
give extra length to the connecting
wires.
]
5