Anleitung_DS_150_200_SPK7:Anleitung BNTS 150-200 SP#1CFA8
Load factor:
A load factor of S2 30 min (intermittent periodic
duty) means that you may operate the motor
continuously at its nominal power level (250 W)
for no longer than the time stipulated on the
specifications label (30 minutes ON period). If
you fail to observe this time limit the motor will
overheat. During the OFF period the motor will
cool again to its starting temperature.
Noise emission levels
The noise emitted by this saw is measured in
accordance with EN ISO 3744; EN ISO 11201
The noise at the workplace may exceed 85 dB
(A). The user will require noise protection
measures if this is the case. (Wear ear-muffs!)
No-Load operation
Sound pressure level L
pA
Sound power level L
WA
5. Installation
5.1 Assembling the spark deflector (Fig. 1/3/4/5)
Fit the spark deflector (3) to the safety hood (4)
using the screws (10), as shown in Fig. 4.
Adjust the spark deflector (3) using the adjusting
screw (11) so that the distance between the dry
grinding wheel (5) and the spark deflector (3) is
as small as possible and certainly does not
exceed 2 mm.
Adjust the spark deflector (3) periodically to
compensate for wear on the wheel.
5.2 Assembling the workpiece support (Fig. 2/6)
Fit the workpiece support (7) to the workpiece
support holder (15) using the workpiece support
fastening screw (6), washer (12), lock washer
(13) and workpiece support locking knob (14), as
shown in Fig. 6.
6. Before starting
The machine must be set up so that it stands
firmly, i.e. it must be securely screwed to a work
bench or similar.
All covers and safety devices have to be properly
fitted before the machine is switched on.
It must be possible for the grinding wheel to run
freely.
Check that the voltage on the rating plate is the
same as your supply voltage before you connect
the machine to the power supply.
7. RCD plug (Fig. 7)
Connect the RCD plug (16) to the power supply.
Press the reset button (17) and the control lamp (18)
will begin to shine. Press the test button (19) to check
the function of the RCD plug. If everything is working
properly the control lamp (18) will go out and the
contact to the power supply will be interrupted. The
RCD plug triggers at a fault current of 30 mA.
Defective RCD plugs must be replaced by a qualified
electrician.
Press the reset key (17) again in order to be able to
start up the machine.
81,5 dB
8. Maintenance
94,5 dB
Important! Pull out the power plug first.
Remove dust and dirt regularly from the machine.
Cleaning is best carried out with a fine brush or a
cloth.
Never use caustic agents to clean plastic parts.
9. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
11.11.2008
10:18 Uhr
GB
13
Seite 13