SPECIFICATIONS
Dimensions
Weight
Voltage
UV tube
Power
Protection index
Conform to NF EN 60335-1 and 60335-2-59. EU approved.
SETTING-UP (SEE FIGURES 1 - PAGE 2 )
y Connect these insect killers to a 16A + ground female socket (13A for the UK), and controlled by a highly sensitive diffe-
rential device protected against power surges.
y Electric model (730109 - 730110 – 730111) : it may be hung by the two rings, fixed to a wall by means of both bolts and
bushings or simply put down.
y For optimum efficiency, install your insect killer two meters from the ground, in the darkest part of the room. In large
rooms, preferably install several devices, distributed so that ultraviolet light diffuses in all corners.
y For the glue insect killer : before use, remove the glue plate protection film, while applying the following safety instruc-
tions.
y Safe installation :
- to be installed in vertical position.
- should only be used inside.
- must not be used in barns, stables and equivalent premises.
- must not be used in rooms where flammable or explosive dust might be present.
- the device must be placed out of children's reach.
y This equipment is not intended for use by individuals (including children) with reduced physical, mental or sensory capa-
cities, or by individuals lacking the necessary experience or knowledge, unless they have received supervision or prior ins-
tructions relating to the use of the equipment by an individual responsible for their safety. Children should be supervised
in order to ensure that they do not play with the equipment.
y Replacing the glue plate (insect killer 730116):
- Disconnect the device.
- Open the front panel upwards.
- Remove the used glue plate by holding it by the two non glued edges.
- Thoroughly clean the device.
- Remove the protection film of the plate to install by holding it by the two non glued edges.
- Fit the plate while avoiding contact of the hands on the glued face. Glued face turned to the outside.
- Close the front panel.

CLEANING AND MAINTENANCE

y Electric model (730109 - 730110 - 730111) : The insect recovery tray must be emptied regularly depending on the type of
use. Weekly emptying is recommended. For that purpose, pull out the tray on plastic lugs side.
y Prior to any maintenance operation, disconnect the device.
y Should you wish to clean electrocution grids, do not remove protection facades, and use a non-conducting object to
detach insects.
MAINTENANCE
y Prior to any maintenance operation, disconnect the device.
y For optimum efficiency, replace the bulbs every year.
y Replacing the bulbs and starter :
* Electric model (730109 - 730110 - 730111) - See figure 2 page 2 :
- remove the recovery tray. An additional safety by means of micros-witch will cut power supply.
- turn the insect killer over and replace the bulbs or the starter.
* For the glue model (730116):
- Open the front panel upwards.
- Change the lamps or starter.
This equipment carries the recycling symbol in accordance with Directives 2002/95/CE and 2002/96/CE relating to
Waste Electrical or Electronic Equipment (DEEE or WEEE) At the end of its working life the equipment should be recycled
in accordance with the regulations that are in force in the country of its installation.
- 4 -
731109
731110
Plus zap 16
Plus zap 30
365x130x262 mm
514x130x262 mm
3 kg
3,5 kg
220/240 V single phase 50 Hz
2 x 8 W
2 x 15 W
25 W
45 W
21
21
731111
730116
Plus zap 80
665x130x262 mm
470 x 90 x 285
5 kg
4 kg
2 x 40 W
2 x 15 W
105 W
45 W
21
21