Position the dispenser so that it cannot open accidentally. Otherwise, oil
could leak onto the ground.
•
When not in use, turn off compressed air to stop pump.
•
Empty all the oil from the pump in case it has to be disposed of.
•
Do not throw oil away. Used oil has to be disposed of according to
national environmental regulations.
6
Maintenance
WARNING!
Risk of personal injury.
• Leaks or other fine jets of liquid under high pressure can cut the skin.
• Make sure that the system is not under pressure before dismantling or
servicing it.
Inspect the equipment regularly for leaks.
If an oil-mist lubricator is fitted, make sure that it is filled with oil.
If a water separator is fitted, empty it.
Make sure that the drum lid is properly fitted to prevent contamination of the
contents.
When changing drums, be careful not to get dirt on the suction pipe or follower
plate, if used. It is recommended to hang up the pump when changing drums.
Use only original spare parts if the pump has to be repaired or its components
have to be replaced.
6.1
Spare parts
CAUTION! Risk of equipment damage.
Use only original spare parts.
Contact your nearest authorized distributor or Nederman for advice on
technical service or if you require help with spare parts. See also www.
nederman.com.
•
When ordering spare parts always state the following:
•
Part number and control number (see the product identification plate).
•
Detail number and name of the spare part (see www.nederman.com).
•
Quantity of the parts required.
6.2
Recycling
The product has been designed for component materials to be recycled. Its
different material types must be handled according to relevant local regulations.
Contact the distributor or Nederman if uncertainties arise when scrapping the
product at the end of its service life.