Set Access Mode
Programming Step
1. Enter Program Mode
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi cards/PINs access
3. Exit Program Mode
Set Audible and Visual Response
Programming Step
1. Enter Program Mode
2. Control Sounds
OR
2. Control LED
3. Exit Program Mode
Reset User's
1. *(Master code) #
2. 2
3. *(Master code) #
(Factory default is 123456)
Reset to Factory Default
1. Power OFF.
2. Connect GND and OPEN.
3. Power ON.
4. There will be two beeps, and the LED light turns into orange.
5. Connect GND and OPEN or must press the Exit Button for at least 10 seconds before release.
THE USER'S INFORMATION IS STILL RETAINED
Keystroke Combination
* (Master Code) #
4 0 #
4 1 #
4 3(Factory default)
4 3 (2~9) #
*
Keystroke Combination
* (Master Code) #
OFF = 7 0 #
OFF = 7 4 #
*
17
ON = 7 1 #
ON = 7 5 #
(Factory defaults are ON)