Technical Data
Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
Hot water temperature
Temperature scale
Safety stop
Flow capacity at 3 bar
Hand shower (1)
Body showers, 4 jets
Tub spout (2)
Handshower
Shower holder
Shower hose
Tray
Bodyshower
Triostat
(Thermostic mixer with shut
off and diverter unit)
Sidecover (Wall installation)
Frontcover
Aluminium
profile
Tub spout
0.2 MPa
max. 1,0 MPa
0.2 – 0.5 MPa
1.6 MPa
max. 70°C
20 – 60°C
11,2 l/min
11,8 l/min
12,9 l/min
Flow heater:
Applicable for flow heaters at min. 24 kW and 0.2 MPa flow
pressure before the Shower panel. Only one consumer pos-
sible, not two simul-taneously.
Pressure differences:
The pressures of the cold and hot water connections must
be balanced.
Maintenance:
The non return valves must be checked once a year.
non return
valve
38°C
Fittings / Technical Data