Descargar Imprimir esta página

Flotec EVO-MULTIMAX 340 LOGIC SAFE Manual De Instrucciones página 21

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
Evo-Multimax340 Logic Safe and Evo-
Multimax 550 Logic Safe pumps are fitted
with an integrated electronic device, LO-
GIC SAFE, that controls the electric para-
meters of the electropump and the water
temperature, by registering the differen-
ce between the pre-set values and those
generated by dry running, motor overload
and water over-temperature anomalies
Control Panel
Green LED light on: "Power-on" Pump
connected to the power supply
Yellow LED light on "Pump-on" Pump
running
Yellow LED light on "Pump-on" Pump
running and the device has registered
the "dry running" anomaly. If the anomaly
lasts it generates the definitive alarm (
red blinking led).
Red LED light "Failure" motor overload
RED blinking led "Failure": dry running or
water overtemperature
Green Led "Restart": reset after anomaly
Dry running
The pump will stop in case of dry-running.
The parameters has been tuned accor-
ding with the pump characteristics.
Note: just a dry-running condition is pre-
liminary identified the yellow "Pump on"
LED begins to blink. If this condition lasts
a fault dry-running condition is genera-
ted.
This fault will be indicated by the blinking
red LED "Failure".
To restore the device press the green "Re-
start" button.
Overload
The pump will stop in case of an overload
(abnormal absorbed current).
When the absorbed current exceeding the
nominal value of the pump, the device will
stop the pump and protect it from power
surges.
This fault will be indicated by the steady
red LED "Failure".
To restore the device press the green "Re-
start" button.
Overtemperature
The pump will stop when the water tem-
perature exceeds a fixed critical value
This fault will be indicated by the blinking
red LED "Failure".
In this case it is necessary to wait for it to
cool before resuming use.
To restore the device press the green "Re-
start" button.
Resect functions
Removing the cause of the anomaly
Press the RESTART button to restart the
equipment and the system as normal. If
the power is cut off, the
machine will automatically be restored to
a serviceable condition when it returns.
MAINTENANCE
Before any intervention on the
pump, disconnect the electrical
mains. Ensure that the electrical
ENGLISH
21 21

Publicidad

loading