X12CLA
 ON: (Blue) When lit, the equipment is ON and the AC input level is within the
permitted range (up to 250 VAC).
 >250V OVERVOLTAGE PROTECTION: (Red) When activated, the AC
voltage is permanently out of the permitted range of the equipment, so it will
remain under protection until this condition is solved. Revise your connections
and mains power installation and consider that other equipment connected to
this line may have been damaged.
I) AC MAINS INPUT/LINK: Mains supply connection via PowerCon.
 Blue connector for AC in.
 Grey connector to feed other units in parallel. Linking up to 4 units is possible,
provided that a quality cable of a minimum section of 3x2.5mm
Connecting more than 4 units in parallel may lead to a voltage drop in the cable
that will reduce the equipment performance.
Always use mains power cable supplied by manufacturer.
Never connect the Xcellence cabinets to an unearthed mains supply or by
using an unearthed mains cable.
4. CONNECTING

4.1. Parallel connection

Connect the signal (mixing desk output) to INPUT on the first unit. Use the LINK
output to transfer the INPUT signal to the second unit and thus sequentially for
further units. All of the units in this chain must be switched on.
For the mains connection in parallel use the cable with grey Neutrik PowerCon
NAC3FCB at one end and the blue Neutrik PowerCon NAC3FCA at the other end.
Do not connect more than four X12CLA units using the AC Mains link
connector. Do not connect Xcellence series units in parallel using
PowerCon-PowerCon without earth.
Fig.8. Parallel connection for the Xcellence series (signal)
9
July 2016
2
is used.