3) insert the steel cords (C1) inside;
4) lock them rotating the knurled cylinder clockwise, after having controlled that the range
hood is at the required height "Y". Use a spirit level to verify the range hood planarity in the
two directions.
5-6) Insert the range hood power cable (CA) in the hole of the support cover plate (C) and
connect it to the terminal (MA) complying with the provisions of sect D.
(Fig. E)
1) Place the terminal inside the support (SC);
2) lift the support cover plate (C);
3) tighten the support cover plate (C) to the support (SC) using 2 screws (V4).
4) Power the range hood electrically.
M2
WALL BEARING HOOD ASSEMBLY INSTRUCTIONS
(Fig. A)
1) Disconnect the electric installation powering the hood. Make sure to install the unit on the
wall (Solution A or B) arranged for the power supply of the hood according to the applicable
regulations.
2) If the power cable of the hood equipment (CAI) is behind the hood bearing (SP) (Solution
A), pass it through its proper hole (F).
3) Place the hood bearing (SP) at the distance Y by taking into account that the distance
between the hood and cooktop is about 60-65 cm. Fix the wall bearing by using 4 screw
anchors having a Ø of 8 mm and the proper screws V1.
(Fig. B1)
Solution A ->
the hood bearing (SP) at the estimated distance X1.
- Temporarily place the hood near the bearing (SP) and connect the power terminal (MA) to
the hood power cable (CA) meeting to the phase, neutral and ground requirements (see
sec. D), and cut the excess cables.
- Place the terminal and power cable between the back of the hood and the bearing SP in
such a way that it is not visible.
(Fig. B2)
Solution B (most common) ->
case it is advisable to fit a plug equipped with a phase, neutral and ground wire on the hood
power cable (CA) in accordance with the applicable regulations.
(Fig. C)
- Secure the hood to its support (SP) by using the standard screws (V2). Act on the bolt B1 to
adjust the hood inclination.
(only for Solution B)
- Supply power to the hood.
the power cable of the hood equipment (CAI) is placed exactly on the back of
the electrical outlet (PE) is placed near the hood. In this
Connect the hood to the supply mains.
17