TRP SLIMCOOL Instrucciones De Montaje página 36

Ocultar thumbs Ver también para SLIMCOOL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
SLIMCOOL
EN
Detailed instructions on the installation of power cables with access
Open the top right glove compartment cover and
6
remove the two screws from the bottom section. (A)
6
A
Slightly separate the glove box and gather in the
6a
original wiring by inserting your hand through
the lower side. This cabled line is protected
by a 40 amp fuse in the original central fuse
boxes.
If the existing terminal is already being used
!
(for example, connected to a microwave), add
a new terminal, similar to the existing one, from
the glove compartment to the central box.
Protect the power cable with a separate 40 Amp
fuse. (Set aside the 40 Amp. fuse in the central
fuse box).
Direct the cabled line of the unit between the
6b
roof and the upholstery above the glove box and
plug in both connectors. Once connected, the
unit will carry out a test function; all the lights go
on and off, indicating that the unit is ready.
Secure the cabled line of the unit to the aluminium
support with plastic flanges, as shown in the
image.
IMPORTANT
If the cabled line is mistakenly connected with the polarity inverted, the electronic control in the unit will beep.
Do not touch any buttons on the panel or remote control, as this may produce irreparable damage in the
electronic system. If you hear these beeps, disconnect the unit and check the connection polarity.
through the top right glove compartment
6
6a
6b
36

Publicidad

Tabla de contenido
loading

Productos relacionados para TRP SLIMCOOL

Tabla de contenido