Descargar Imprimir esta página

Tetra PL 20 Instrucciones De Uso página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
UK
Placing in service
1. Connect the safety transformer at a location where it is dry and cannot be flooded. The
transformer must have at least 2 m clearance to the edge of the pond.
2. Place the halogen spotlight in the pond or next to the pond to a stable base.
3. Layout the power cord and connect it to the safety transformer.
Caution! The halogen spotlight heats up in normal operation.
Changing the bulb
1. Disconnect the light or the safety transformer from the mains power and secure it from being
switched on unintentionally.
2. Dry off the halogen spotlight.
3. Unscrew the screw ring (5) from the bulb housing (1).
4. Remove the protective glass (4) and the flat seal (3).
5. Take bulb (2) out of its mounting and replace it.
Caution! Do not touch the bulb directly with your hand as this significantly reduces the service life
of the bulb. Use a piece of paper or a soft cloth to replace the bulb.
6. The power consumption on the bulb and that on the nameplate must agree.
7. Replace the flat seal (3) and the protective glass (4).
8. Screw the screw ring (5) onto the bulb housing (1).
The replacement bulbs, type MR16, are available in specialist departments of high-street stores.
Wearing parts
Bulbs are wear parts and are excluded from the warranty.
Cleaning
1. Disconnect the light or the safety transformer from the mains power and secure it from being
switched on unintentionally.
2. Clean the halogen spotlight with warm water without cleaning agents using a soft brush or cloth.
Ensure that no moisture gets into the bulb housing.
Storage/Wintering
If frost is expected, then you must remove the halogen spotlight. Thoroughly clean the device (see
Cleaning). Check the garden and pond spotlight for damages. Store the garden and pond spotlight in
a dry and frost-free location. Children must not have access to the storage location.
Contact Tetra technical support
Neither the transformer nor the spotlight can be repaired in the event of damage to the cables or the
housing and must, therefore, be replaced.
Disposal
Dispose of the unit in accordance with the national legal regulations.
6
Problem solving
Problem
Cause
Bulb is not illuminated Power supply interrupted
Light performance
Dirt on protective glass
is decreased
Water in the
Seal defective
halogen spotlight
Light flickers
Contacts have corroded
Optional fitting to TetraPond FP fountain pump
1. Loosen and remove the screw from the foot (6)
2. Disconnect the brace holding the spotlight from the foot
3. The cavity on the pump housing is intended to fit the spotlight
4. Fix the brace in this cavity and secure with the screw
5. Align the spotlight as required
Pond keeping information
If you have any questions regarding your pond or water garden contact Tetra at: Tetra (UK) Ltd, P.O.
Box 271, Southampton, SO18 3ZX or visit our Web Site on http:\\www.tetra.net
2 YEAR GUARANTEE
Tetra guarantees that this TetraPond unit will be repaired or replaced free of charge within two
years from the purchase date, if it fails due to defective materials or poor workmanship.
This guarantee does not cover normal wear and tear, nor any deterioration suffered through
overloading, improper use, negligence or accident. Similarly any modifications made by the
purchaser to the appliance will cause the guarantee to be null and void. Please keep your receipt
as proof of purchase and return the enclosed guarantee card within 14 days in order to validate
your guarantee.
UK
Remedy
Check power feed and fuse, check bulb,
and replace contacts if necessary
Cleaning
Check seal and replace if required
Clean the bulb pin
7

Publicidad

loading

Este manual también es adecuado para:

Pl 60