Type
of
Max.
Max.
cable
distance
distance
entry
VA/301 >
panel>
monitor
VA/301
VCM/1D
0-100 m*
0-100 m
VCM/2D
0-100 m
0-30 m
UTP/5
(AWG24-
0-100 m*
0-20 m
2
0,2mm
)
T w i s t e d
pair
0-100 m*
0-30 m
2
(0,28 mm
)
S y m -
metrical
0-100 m*
0-80 m
pair cable
(1 mm
2
)
* more than two wires of 1 mm
2
PROGRAMMING
VIDEO ENTRY CONTROL YVL301
STANDARD PROGRAMMING
(without the need to use the software PCS/300)
To programme the call in system 300 installations, see the
literature enclosed with the XA/300LR control unit.
If programming the 2nd and 3rd call from the entry panel,
simply press the keys subsequently corresponding to the
first call button.
NOTE. Do not exit receiver programming mode until you
have associated all the desired calls.
PROGRAMMING WITH PCS/300
The unit can be programmed through the PCS/300 by
selecting the corresponding receiver.
PROGRAMMING MELODIES AND NUMBER OF RINGS
To enter programming mode, lift the receiver and press
the button underneath A (fig. 8) 5 times, within 5 s.
A short audible signal sounds to confirm you have entered
programming mode (you automatically enter the entry
panel call melody programming procedure).
To repeat the procedure to enter programming mode, hang
up and wait at least 5 s.
Press the door lock release button to run through the
different modes in sequence.
A number of short audible signals sound to indicate that
you have entered the corresponding mode:
no. 1 audible signal: programming of melody associated
with the call from the entry panel.
no. 2 audible signals: programming of melody associated
with doorbell.
no. 3 audible signals: programming of number of rings
announcing a call.
1 - Programming of melody associated with the call
from the entry panel
The first entry panel call melody is played repeatedly,
alternated with a short audible signal. To listen to the
next melody, press the auxiliary button 2 ( ) during the
pause between the audible signal and melody. Repeat
the operation until you hear the melody you want.
To save the new setting without programming anything
else, hang up; otherwise, press the door lock release
button to call up the next programming procedure.
2 - Programming of melody associated with doorbell
The first doorbell melody is played repeatedly, alternated
with two short audible signals.
To listen to the next melody, press the auxiliary button 2 ( )
during the pause between the audible signal and melody.
Repeat the operation until you hear the melody you want.
To save the new setting without programming anything
else, hang up; otherwise, press the door lock release
button to call up the next programming procedure.
3 - Programming of number of rings announcing a call
Three short audible signals sound.
Decide how many rings you want and press the auxiliary
6
button 2 ( ) the corresponding number of times (in the
Max.
Total
range 1 to 6).
distance
amount
In system 300 installations, you can increase the
entry
of cable
number of rings to a maximum of 51 by customizing
panel >
laid
control unit XA/300LR.
monitor
3 s after the button was last pressed, you will hear the call
100 m
600 m
selected for the chosen number of rings.
100 m
600 m
If you want to save settings without programming
anything else, hang up; otherwise, press the door lock
100 m
400 m
release button to enter the entry panel call melody
programming procedure again.
NOTE. When you exit programming mode, the last settings
100 m
250 m
selected for each programming procedure are saved.
For a setting to be taken as selected, you must have heard
it at least once.
100 m
250 m
VIDEO ENTRY PANEL HEV/301
PROGRAMMING OF NUMBER OF ENTRY PANELS
(only required where there is more than one entry
panel)
1 - Start with the last entry panel connected in series
to the bus (usually the one with terminals B IN not
connected).
2 - Remove jumper SW1.
3 - Wait for the note confirming the operation
(approximately 3÷15 s).
The number of confirmation signals also indicates the
number of present and programmed entry panels (1
signal for the main entry panel and 1 signal for each
secondary entry panel).
4 - Refit jumper SW1.
PROGRAMMING RECEIVERS
1 - Remove jumper SW2 from any entry panel.
2 - Lift the handset of the receiver to be programmed (for
telephone sets, see the instructions featured in interface
IT/300).
3 - Press the door-lock release and auxiliary 2 buttons at
the same time for at least 1 s (when audio towards the
entry panel is enabled, the operation is confirmed).
4 - On the entry panel, press the call button the receiver
is to be associated with.
5 - Replace the handset.
6 - Repeat the operation from point 2 on for all remaining
receivers.
7 - Refit jumper SW2 to exit programming.
WARNING.
the VSE/301 selector, where fitted, must only be
performed once you have programmed which calls
from the entry panels are to be associated with which
receivers.
In installations with XA/300LR we recommend you
gather up the receiver's ID (SN) codes, applied on the
outside of the housing, and enter them in the tables
that come with the XA/300LR and IPC/300LR.
NOTE. Once the power supplier has been
programmed using a PCS/300 unit, it will no longer
be possible to gain access to the entry panel standard
programming.
To restore default conditions, please refer to the
related chapter.
Return to default conditions from entry panel
1 - Remove the SW1 jumper.
2 - Close the earthed door open contact.
A sound signal confirms that the operation has occurred.
3 - Replace the SW1 jumper
TECHNICAL FEATURES
VIDEO ENTRY CONTROL YVL301
• Power supply from bus: 15÷20 VDC.
• Current demand: 600 mA max (< 1 mA quiescent).
• Number of receivers activated at the same time by X1
BUS: 1.
• Maximum number of receivers that can be connected
to control unit XA/300LR: 100.
The
programming
procedure
• Maximum number of receivers that can be connected
to an X1 entry panel: 64 (100 with XAS/301).
• X1 connection line: non polarized twisted pair Z=100 Ω.
• CCIR (EIA) standard.
• Picture screen: 4" (10 cm).
• Bandwidth response at -3 dB: 5 MHz.
• Horizontal frequency: 15,625 Hz (15,750 Hz EIA).
• Vertical frequency: 50 Hz (60 Hz EIA).
• Working temperature range: from 0 °C to +35 °C.
• Dimensions: 206x215x59 mm.
VIDEO ENTRY PANEL HEV/301
• Power supply:
14÷18 V DC.
• Current demand:
- on stand-by with 14V DC max. 230 mA;
- operating with 14V DC max. 380 mA;
- with door-lock release activated, add 500 mA;
- for each HEP/306-HEP/312D, add 35 mA;
- for each XDV/300A connected, add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of video signal.
• Door-lock release command: pulse-type for solenoid
lock at 12 V 1 A.
• Timed solenoid door-lock release: adjustable in the
range 1 to 15 s.
• Installation activation time: 60 s.
• Call duration time: 30 s.
• Bus output: power supply at 15 V DC for booster and
receivers video driver balanced type (Z = 100 Ω).
• Aux 1 command output: 3.5 V DC at 1 mA (available
only with entry panel enabled, activation time same as
timed solenoid door-lock release).
• Aux 2 command output: 3.5 V DC at 1 mA (always
available in all entry panels, activation time same as
timed solenoid door-lock release).
• Entry panel activation output: 3.5 V DC at 1 mA
(enabled for entire duration of conversation).
• Video signal system: CCIR (EIA).
• Sensor: 1/4" CCD.
• Horizontal frequency: 15,625 Hz (15,750 Hz EIA).
• Vertical frequency: 50 Hz (60 Hz EIA).
• Video output: 1 Vpp composite to 75 Ω.
• Resolution: 380 lines.
• Minimum illumination: 5 lx.
• S/N ratio: 45 dB.
• Iris control: automatic electronic in the range 1/50 s
1/100,000 s.
• Lens: fixed-focus f 3.7 F 4.5.
for
• Working temperature range: -15 °C to +50 °C.
• Dimensions: 207x99x13 mm.
POWER SUPPLIER VA/301
• Supply voltage: 230V AC 50/60 Hz, +6% –10%.
The transformer is electronically protected against
overloading and short circuiting i.e. no fuses are used.
• Power demand: 60 VA.
• Entry panel and accessories supply: 18V DC 0.8 A
(terminal block M1).
• Receiver power supply through bus: 20 VDC (terminal
block M2).
• The VA/301 unit, on its own, can supply:
- 1 audio/video entry panel, up to 64 pushbutton calls
or with digital keypad HAC/300LR;
- 1 active X1 monitor and 63 on standby;
- 2 XDV/300A amplifiers.
• Number of receivers that can be activated by the same
call: 8 (6 with attenuated note).
• Maximum distance between entry panel and last
receiver 100 m, with cable VCM/1D (VA/301 can be
positioned at any point between the entry panel and
first receiver).
• Working temperature range: da 0 °C to +35 °C.
• Dimensions: 12 DIN units module, low profile (fig. 29).
DISPOSAL
Do not litter the environment with packing material: make
sure it is disposed of according to the regulations in force
in the country where the product is used.
When the equipment reaches the end of its life cycle,