WARRANTY
The new equipment is covered by warranty.
The warranty conditions are provided by the distributor.
The manufacturer is not liable for any inaccuracies in this booklet resulting from printing or
transcription errors. The manufacturer reserves the right to modify its products as it consid-
ers necessary or in the interests of the user, without compromising their essential safety and
operating characteristics.
N
RANGE HOOD ASSEMBLY
WARNING: Failure to install the screws or fixing device in accordance with these instructions
may result in electrical hazards.
Set the hole on the false ceiling, according to the indications of the drawings at the beginning
of the booklet. Fix the provided jig on the internal part of the false ceiling, so not to be visible,
to increase the reinforcement, as indicated in figure (OA-OB-OC).
Note:
if the MU is installed on the hood and on the FC flange connection and the plastic check valve
is used, it is recommended to install the latter on the conveyor outlet. The installation instruc-
tions are found inside the valve packaging.
ATTENTION, the false ceiling must be suitably reinforced to safely support the range hood.
Remove the AP openable panel and the metallic filters (see fig. 1A).
Find installation type for outside exhaust version:
With motor unit (UM) (MU) fixed on the range hood:
1) Remove the FC flange assembled on the range hood and the FM flange assembled on the
UM (fig. 1B). Define the direction of air outlet by rotating the FL flange of the motor unit (see
fig. 2). Fix UM to the range hood according to the output direction of the wanted air (see fig.
3).
2) Fix the safety chains to the ceiling using the provided screws and wedges (see fig. 4).
3) Lift the range hood near to the false ceiling: connect the UM (MU) motor outlet to the air
discharge duct using a flexible pipe. Carry out electric connection only after having discon-
nected the electric power supply powering the range hood. Introduce the safety chains
inside the made holes in the upper part of the range hood (fig. 5).
4) Place the hood in the false ceiling, which has been previously reinforced. When opened,
hooks G hold temporarily the hood to the false ceiling.
Fasten all screws (B) by rotating them clockwise, so to open the hooks and block the hood
on the panel of the false ceiling.
To remove the hood from the false ceiling, unfasten screws B by rotating them counter-
clockwise, paying attention to hold the hood appropriately to prevent it from falling. Fix the
chain to the hood by using the provided screws and remove the exceeding links. Ensure the
hood is fixed properly to the false ceiling (see fig. 5).
5) Allocate the metallic filters and the AP panel again.
Remote motor positioned in a technical compartment protected against at-
mospheric agents inside the residence: define the type of output
- Rectangular output of 90x220 mm (fig. 6). Remove the FC flange fixed on the range hood and
assemble the flange for FR rectangular pipe (optional). Install UM in the wanted position.
- Circular output diam 150 mm (fig 7). Verify that the FC flange is assembled on the range hood.
27