5. PROGRAMMAZIONE
IL SERT À RÉGLER LE DÉLAI
DE L'INTERVENTION POUR
LA PROTECTION
DU COURANT
RANGE 1 ÷ 8s
CURRENT DELAY
4 s
CURRENT DELAY
4 s
IL SERT POUR RÉGLER
LE DÉLAI D'ACTIVATION
DE LA SORTIE D'ALARME
RANGE 1 ÷ 250min
ALARM DELAY
1 min
ALARM DELAY
OFF
OFF EXCLUT LE DÉLAI
D'ALARME
ALARM DELAY
OFF
MAXIMUM VOLTAGE
OFF
RANGE 400 ÷ 440V
MAXIMUM VOLTAGE
440 V
MAXIMUM VOLTAGE
440 V
ON: ACTIVE L'ALTERNANCE ENTRE LES MOTEURS
OFF: DÉSACTIVE L'ALTERNANCE ENTRE LES MOTEURS
MOT. ALTERNANCE
OFF
MOT. ALTERNANCE
ON
MOT. ALTERNANCE
IL SERT POUR DÉFINIR LE
TEMPS D'ATTENTE DU RÉSEAU
RANGE 1 ÷ 30min
SUPPLY MAINS
WAITING 1 min
SUPPLY MAINS
WAITING OFF
OFF EXCLUT L'ATTENTE
PRÉSENCE AU RÉSEAU
SUPPLY MAINS
WAITING OFF
OFF EXCLUT LE CONTRÔLE
SUR LA TENSION MAXIMALE
IL EST UTILISÉ POUR RÉGLER LA
TENSION DE FONCTIONNEMENT
MAXIMAL DES MOTEURS
STABLE DÉMARRE LE MOTEUR AVEC
UN PULSE SUR LE BOUTON MAN;
ARRÊTE LE MOTEUR AVEC UN
PULSE SUR LE BOUTON RESET
INSTABLE DÉMARRE LE MOTEUR
SEULEMENT PENDANT
LA PRESSION SUR LE BOUTON MAN
ON
OFF EXCLUT LE CONTRÔLE
SUR LA TENSION MINIMALE
IL EST UTILISÉ POUR RÉGLER LA
TENSION DE FONCTIONNEMENT
PRESSEZ POUR VOIR LA PARTIE
RESTANTE DE PARAMÈTRES
VOIR CHAPITRE 5.1
PRESSEZ POUR PLUS DE 1S POUR
QUITTER LE SETUP ET ENREGISTRER
LES PARAMÈTRES DANS LA MÉMOIRE
10
MANUAL BUTTON
STABLE
MANUAL BUTTON
UNSTABLE
MANUAL BUTTON
UNSTABLE
MINIMUM VOLTAGE
OFF
MINIMAL DES MOTEURS
RANGE 342 ÷ 380V
MINIMUM VOLTAGE
360 V
MINIMUM VOLTAGE
360 V