ARVEN MIZAR 30 Manual De Instrucciones página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
FAULT
4.The flow rate is
insufficient.
5.The overload protec
tion device stops the
pump.
DON'T DISPOSE OF WORN-OUTS UNITS THROUGH THE
HOUSEHOLD GARBAGE
The appliance, its packaging and accessories are all produced from
recyclable materials and must be disposed of accordingly, in the suita-
ble dispose places, adhering itself to the modalities previewed from the
enforced norms in matter
30
CHECK (Possible cause)
A .Ensure that the suction filter is
not partlyblocked.
B. Ensure that the impellers or the
delivery pipe are not partly
blocked or fouled with scale.
C. Ensure that the check valve (if
fitted) is not partly clogged.
D. Check the direction of rotation
in three-phase versions (See
Chapter on Electrical connection
- Paragraph 8.4.).
A.Ensure that the fluid to be
pumped is not too dense
because it would cause
overheating of the motor
B.Ensure that water temperature
is not too high (see liquid tem
perature range).
C.The pump is partly blocked by
impurities.
D.The pump is mechanically
blocked.
REMEDY
A.Remove any obstructions, as
indicated in the chapter on
Warnings (Paragraph 6.4.).
B. Check good operation of the
valve and replace it if necessary.
C. Accurately clean the
check valve.
D. Invert two wires in the
power cable.
B Reduce liquid temperature.
Wait until thermal protection
switch resets, about 20 mins.
C. Accurately clean the pump.
D.Check for the occurrence of
rubbing between moving and
fixed parts; check the state of
wear of the bearings (contact
the supplier).

Publicidad

Tabla de contenido
loading

Tabla de contenido