General Information; Technical Specifications - BFT MOOVI AC 30 Instrucciones De Uso Y De Instalacion

Automatismos electromecanicos para barréras vehicular
Ocultar thumbs Ver también para MOOVI AC 30:
Tabla de contenido

Publicidad

1) GENERAL INFORMATION

Compact electromechanical barrier suitable for enclosing private areas and
car parks and for use across entrances used by vehicle traffic only. Available
for entrance/exit points between 3 and 5 metres across. Adjustable electro-
mechanical limit switches ensure the boom stops in the correct position.
The emergency release for manual operation is operated by a lock with a
personalized key.
The actuator is always supplied ready for assembly on the left.
Where necessary, the opening direction can always be reversed with a few
simple operations. The foundation base mod. CBO (on request) can be
supplied to make the barrier easier to install.
Provision for accessories makes installing them straightforward, with no
need to drill additional holes.

2) TECHNICAL SPECIFICATIONS

220-230 V 50/60 Hz
Power supply
110-120V 50/60 Hz
Max. power input
300W
Capacitor
8µF 450V (220-230V): 32µF 250V (110V)
Current demand
1,4 A: 2.8 A
(with accessories)
Insulation class
F
Internal lubrication lifetime greased
85 Nm (MOOVI 30) / (MOOVI 30 RMM)
Max. torque
250 Nm (MOOVI 60) / (MOOVI 60 RMM)
72 Nm (MOOVI 30S)
4s (MOOVI 30) / (MOOVI 30 RMM)
Opening time
8s (MOOVI 60) / (MOOVI 60 RMM)
1,5s (MOOVI 30S)
3m max (MOOVI 30) / (MOOVI 30 RMM) / (MOOVI 30S)
Boom length
6m max (MOOVI 60) / (MOOVI 60 RMM)
MOOVI 30 - MOOVI 60 SAFETY EDGE
MOOVI 30 RMM
Impact reaction
MOOVI 60 RMM
MOOVI 30 S
Mechanical
personalized key
manual release
Type of boom
rectangular
Limit switches
electric, built-in and adjustable
Type of use
semi intensive
Operating
da -20°C a +55°C
temperature range
Protection rating
IP 24
Actuator weight
35,6 Kg
(without boom)
Dimensions
see fig.A
Sound pressure
<70dB(A)
3.1) FOUNDATION PLATE (Fig.B1)
3.2) ANCHOR BOLTS (Fig.B2)
4) ACTUATOR ASSEMBLY
WARNING! The barrier must be used only for entrance/exit points
intended for vehicle traffic. Pedestrians must not be allowed to pass
within range of the automated system. Make sure there is a separate
entrance/exit just for pedestrians.
The entrance/exit must be suitably signposted with the compulsory
signs illustrated in Fig.A.
WARNING: before opening the door, the spring must be decompressed
(vertical boom). The door in the cabinet must face towards the inside of the
property. Standing in the middle of the entrance, facing out, if the cabinet
is on your left, the barrier is on your left: if the cabinet is on your right, the
barrier is on your right.
The actuator is always supplied ready for assembly on the left.
5) Assembly on left (Fig. A, B, C, D).
- Balance the boom as illustrated in Fig. AB.
6) Assembly on right (Fig. AA).
- Balance the boom as illustrated in Fig. AB.
7) Boom assembly (Fig. D).
INSTALLATION MANUAL
ENCODER OR SAFETY EDGE
8) BOOM BALANCING (Fig. AB).
For Moovi 30:
WARNING! During the closing operation, the balancing spring
must never be fully compressed. Fig.AB rif.3 shows the position
for determining the minimum size that the compressed spring can be
allowed to reach with the boom in the open position (vertical).
9) MOOVI accessories (boom length limits and balancing) (Fig. AF)
For further information on installing and using the accessories, refer to the
relevant instruction manual.
10) FITTING THE FLASHING LIGHT (FIG.AC)
Complete assembly and wiring as directed in instructions provided for the
flashing light.
11) FITTING THE PHOTOCELL (FIG. AD).
Complete assembly as directed in instructions provided for the photocell
12) ADJUSTING THE LIMIT SWITCHES (Fig. E)
13) PREPARING THE ELECTRICAL SYSTEM
WARNING: before opening the door, the spring must be decompressed
(vertical boom). Prepare the electrical system (fig. A), referring to the stan-
dards in force. Keep mains power connections well separated from service
connections (photocells, safety edges, control devices, etc.).
WARNING! For connection to the mains power supply, use a multicore
cable with a cross-section of at least 3x1.5mm
by the regulations mentioned above (for example, it must be at least
equal to H05RN-F).
14) EMERGENCY RELEASE (Fig. Y)
WARNING: When needing to activate the release in an actuator without a
boom, make sure the balancing spring is not compressed (boom in opening
position).
15) TROUBLESHOOTING.
15.1) Boom fails to open. Motor not running.
WARNING: before opening the door, the spring must be decompressed
(vertical boom).
1) Make sure the photocells are not dirty, misaligned or have had their beam
broken.
2) Check that the motor is connected properly.
3) Make sure power is being supplied correctly to electronic equipment.
Check for blown fuses. If a fuse is malfunctioning, remove and replace
as illustrated in Fig. I, J.
4) If the panel is not working, replace it.
5) Grease the spring guide tie rods if you encounter noise or vibrations.
15.2) Boom fails to open. Motor running but there is no movement.
1) Manual release is still engaged. Reset to motorized operation.
2) If the release is in the motorized operation position, check the gearbox
for damage.
MOOVI AC 30-60 / MOOVI AC 30-60 RMM / MOOVI AC 30 S -
of the kind provided for
2
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Moovi ac 60Moovi ac 30 rmmMoovi ac 60 rmmMoovi ac 30s

Tabla de contenido