Up/Down control buttons (#5). Touch the Up or
Down buttons to increase or lower the temperature
setting as desired. If the set temperature is higher
than the actual temperature the device will
start to heat up immediately. Once the required
temperature is reached, it will be maintained at this
level. To terminate the heating process, adjust the
current temperature setting to '00'.
3.
Setting the time: Press the Set button (#6). The
display will start flashing. You can now program the
cleaning time by pressing the Up/Down control
buttons (#5) to increase or decrease the time.
4.
After setting the time press the Start button (#2)
to initiate the cleaning process. The display shows
'U' while cleaning is in progress. Once the cleaning
time has expired, cleaning will automatically stop.
The display will now show the last saved time setting
(Memory feature).
5.
Memory&Pause: Touch the green Start/Pause button
(#2) to activate the Memory feature. When cleaning
is complete and the green button is pressed the
previous time setting is saved so that the time does
not have to be re-set every time. If the green button
is pressed while cleaning is still in progress, cleaning
will be paused. To restart the cleaning process, press
the green button again.
6.
Degassing: During this process ultrasound is used to
expel gases (e. g. carbon dioxide) from the liquid.
The number of cavitation bubbles that are required
for efficient cleaning can only be formed in degassed
liquids. To activate this feature press the Set button
(#6). The display will show 'D'. You need to press the
Set button again to stop degassing. The display will
then show 'U'.
7.
Once cleaning is complete, switch the device off
(power button #1). Remember to unplug the device
after use. Empty any liquids from the tank and
remove any objects.
18
u l t r a s o n i c c l e a n e r
proclean 2.0DS
7
6
4
sweep
3
degas
8
5
2
1
1
on/off
1.
On/Off button
2.
START/PAUSE & Memory button
3.
Degas button
4.
Sweep button
5.
Temperature control knob
6.
Temperature indicator
7.
Remaining cleaning time indicator
8.
Timer control knob
OPERATION
1.
All the buttons are touch buttons which only re-
quire a light touch. To activate the device and start
the cleaning process, touch the power button (#1)
at the front of the device. You can then select the
required temperature and time settings.
2.
Setting the temperature: If the device is switched on,
a flashing LED indicates the actual temperature of
the cleaning liquid. To set the desired temperature,
turn the temperature control knob (#5) clockwise.
A green LED indicator illuminates while the device
is heating up. Once the set temperature is reached
it will be maintained until the device is switched off.
To switch off the heating function, turn the control
knob anti-clockwise to the zero position.
3.
Setting the time: Turn the Timer control knob (#8)
to set the desired cleaning time. Pressing the Start
button (#2) will activate the device and the clean-
ing process will start. A flashing LED indicates the
remaining cleaning time. At the end of the cleaning
time the cleaning process will stop automatically.
The display will now show the last saved time set-
ting (Memory feature).
Rev. IV 2017
4.
Pause: If you press the Pause button (#2) the
cleaning process will be interrupted until the Pause
button is pressed again.
5.
Degassing: During this process ultrasound is used
to expel gases (e. g. carbon dioxide) from the
liquid. The number of cavitation bubbles that are
required for efficient cleaning can only be formed
in degassed liquids. To activate this feature press the
Degas button (#3). Press the button again to stop
degassing.
6.
Sweep: This optional Sweep feature optimises
the sound field distribution in the cleaning liquid
through frequency modulation. Pressing the Sweep
button (#4) will activate the feature. To turn the
min. 2/3
feature off, press the button again.
7.
Once cleaning is complete, switch the device off
(power button #1). Remember to unplug the device
after use. Empty any liquids from the tank and
u l t r a s o n i c c l e a n e r
remove any objects.
proclean 3.0DSP
MULTIFUNCTION
11
10
12
9
13
8
6
3
pulse
power
5
2
7
14
degas
4
1
sweep
on/off
1.
On/Off button
2.
START/PAUSE & Memory button
3.
Ultrasonic Power setting button
4.
Sweep button
5.
Degas button
6.
Pulse button (wave frequency setting)
7.
Timer control knob (cleaning time setting)
8.
Cleaning process LED
9.
Power indicator
10.
Cleaning frequency indicator
11.
Cleaning time indicator
12.
Temperature indicator for the cleaning liquid
13.
Heating process LED
14.
Temperature
control
knob
(cleaning
liquid
temperature setting)
Rev. IV 2017
OPERATION
1.
All the buttons are touch buttons which only
require a light touch. To activate the device and start
the cleaning process, touch the power button (#1)
at the front of the device. You can then select the
required temperature and time settings.
2.
Setting the temperature: If the device is switched
on, the actual temperature of the cleaning liquid is
indicated on the display. Turn the control knob (#14)
to set the required temperature. The heating process
will start automatically and the display will indicate
that heating is in progress. The set temperature is
maintained as long as the device is switched on. To
stop the heating, turn the Temperature control knob
anti-clockwise to the zero position.
3.
Setting the time: Turn the Timer control knob (#7)
to set the desired cleaning time. Pressing the Start
button (#2) will activate the device and the cleaning
process will start. The remaining time is shown
on the display. At the end of the cleaning time the
cleaning process will stop automatically. The time
display now shows the last saved time setting
(Memory feature).
4.
Pause: If you press the Pause button (#2) the
cleaning process will be interrupted until the Pause
button is pressed again.
5.
Degassing: During this process ultrasound is used to
expel gases (e. g. carbon dioxide) from the liquid.
The number of cavitation bubbles that are required
for efficient cleaning can only be formed in degassed
liquids. To activate this feature press the Degas
button (#5). The corresponding LED will illuminate.
To disable degassing press the button again. The
corresponding LED will go off.
6.
Sweep: This optional Sweep feature optimises the
sound field distribution in the cleaning liquid through
modulation of frequencies. Press the Sweep button
(#4) to enable this feature. The corresponding LED
will light up. To disable the feature press the Sweep
button again. The corresponding LED will go off.